![IAI PSA-24 Instruction Manual Download Page 32](http://html1.mh-extra.com/html/iai/psa-24/psa-24_instruction-manual_604103032.webp)
2.1 Environmental Conditions
2-1
2.
Ins
ta
llat
ion
2.1 Environmental Conditions
Item
Specifications
Terms of use, etc.
Ambient operating
temperature
0°C~+55°C
(With derating)
Natural air cooling (204 W/without fan)
Forced cooling (330 W/with fan)
Ambient operating
humidity
85% RH or less
non-condensing
Ambient storage
temperature
-20°C~+70°C
Atmosphere
Avoid corrosive gas and excessive dust
Altitude
2,000m
Vibration resistance
Frequency 10 to 57Hz /
Amplitude: 0.075mm
Frequency 57 to 150Hz /
Acceleration 9.8m/s
2
XYZ directions
Sweep time: 10 minutes
Number of sweeps: 10 times
Package drop
Drop height: 800mm/1 corner,
3 edges, 6 faces
Overvoltage
category
II
Pollution degree
2
Installation site
Indoors
Degree of protection
Not applicable
Generated heat
28.6W
100 VAC 204 W continuous rated
20.4W
200 VAC 204 W continuous rated
Cooling method
Natural air cooling/
Forced cooling with a fan unit
Summary of Contents for PSA-24
Page 6: ......
Page 17: ...Part Names Intro 11 Part Names PSA 24 204W without fan PSA 24L 330W with fan ...
Page 30: ...1 2 General Specifications 1 7 1 Specifications ...
Page 36: ...2 2 Heat Dissipation and Mounting 2 5 2 Installation ...
Page 55: ...Before Considering Failure 6 1 Before Considering Failure 6 1 Power supply unit Chapter 6 ...
Page 59: ...External Dimensions 8 1 External Dimensions 8 1 Power supply unit Chapter 8 ...
Page 63: ...Life 9 1 Consumable Parts 9 1 Power supply unit Chapter 9 ...
Page 68: ...10 3 10 Warranty ...
Page 83: ......