INSTRUCTIONS FOR THE INSTALLER

assembly is restrained from accidental contact 
with the flue or flue outlet of an underbench oven. 
The hose should not be subjected to abrasion, 
kinking or permanent deformation and should 
be able to be inspected along its entire length. 
Unions compatible with the hose fittings must be 
used and connections tested for gas leaks. The 
supply connection point shall be accessible with 
the appliance installed.
Please select the type which is correct for the 
supply concerned.
Once the installation is complete, check all 
connections for gas leaks with soap and water. 
DO NOT use a naked flame for detecting leaks. 
Ignite all burners both individually and concurrently 
to ensure correct operation of gas valves, burners 
and ignition. Turn gas taps to low flame position 
and observe stability of the flame for each burner 
individually and concurrently. When satisfied with 
the hotplate, please instruct the user on the correct 
method of operation. In case the appliance fails 
to operate correctly after all checks have been 
carried out, refer to the authorised service provider 
in your area.

Electric connection

The connection to the electric grid must be carried 
out by qualified personnel and in conformity with 
the regulations in force.
The voltage of the electric system must correspond 
to the value indicated in the label under the 
appliance. Make sure that the electric system is 
provided with an effective ground connection in 
compliance with the regulations and provisions of 
the law. Grounding is compulsory.

G A S   T R A N S F O R M AT I O N S   A N D 

ADJUSTMENTS

Data Label

A duplicate Data Label is supplied to adhere in an 
accessible area next to the appliance.
This appliance is suitable for Natural Gas and Uni-
versal LPG; ensure that the available gas supply 
matches the Data Label.
When converting from Natural Gas to Universal 
LPG ensure that the NG regulator is removed and 
replaced with the Test Point Assembly. An AGA Ap-
proved gas regulator suitable for a supply pressure 
of 2.75kPa should be part of the gas tank supply 
and the test point pressure should be adjusted to 
2.75kPa.

Replacing the nozzles

If the equipment is adjusted for a type of gas that is 
different from the one available, it is necessary to 
replace the burner nozzles.
The choice of the nozzles to replace must be 

made according to the table of the “technical 
characteristics” as enclosed.
Act as follows: 

remove the racks and burners. 
by means of a straight spanner L, unscrew 
the nozzle U (fig. 8) and substitute it with the 
corresponding one. 
tighten the nozzle strongly. 

Adjusting the burners

The lowest flame point must always be properly 
adjusted and the flame must remain on even if 
there is an abrupt shift from the maximum to the 
minimum position.
If this is not so, it is necessary to adjust the lowest 
flame point as follows:

start the burner up
turn the tap up to the minimum position (small 
flame)
remove the knob from the tap rod
introduce a flat-tip screwdriver C in the hole F of 
the tap (fig. 9) and turn the by-pass screw up to 
a proper adjustment of the lowest flame point.

As regards U-LPG gas burners, the by-pass 
screw must be tightened completely.

MAINTENANCE

Maintenance Schedule

No regular maintenance is required for the hotplates 
except cleaning.

Replacing the power supply cable

If the power supply cable should be replaced, 
it is necessary to use a cable with a section of 
3x0.75mm

2

, type H05VV-F or H05RR-F, complying 

with the regulations in force.
The connection to the terminal board must be 
effected as shown in fig.10 - 10/A:

brown cable L 

 

(phase)

blue cable N  

 

(neutral)

green-yellow cable    (ground)

-
-

-



Summary of Contents for ICD6SG3

Page 1: ...COD 208228 REV1 28 05 2007 Gas Built in Hobs MODEL ICD6SG3 MODEL ICD9SG4 INSTALLATION AND OPERATION MANUAL ...

Page 2: ...ing the equipment cut power supply off and make it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment it may be necessary to improve aeration for example by opening a window or increasing the mechanical suction power if it exists The products of combustion must be discharged out...

Page 3: ...re when overheated Do not spray aerosols in the vicinity of the appliance while it is in operation Do not store or use flammable liquids or items in the vicinity of this appliance Do not place unstable or deformed pots on the burner so as to prevent them from overturning or overflowing Make sure that pot handles are placed properly When the burner is started up check that the flameis regular and b...

Page 4: ...alled to guarantee an adequate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of hooks is also supplied for mounting the cook top Depending on the type of mounting surface the suitable type of mounting hook is supplied hook A o...

Page 5: ...ce is suitable for Natural Gas and Uni versal LPG ensure that the available gas supply matches the Data Label When converting from Natural Gas to Universal LPG ensure that the NG regulator is removed and replaced with the Test Point Assembly An AGA Ap proved gas regulator suitable for a supply pressure of 2 75kPa should be part of the gas tank supply and the test point pressure should be adjusted ...

Page 6: ...6 1 2 3 4 5 6A 6 8 7 9 10 10 A V ...

Page 7: ...isprints or clerical errors It reserves the right to make all the changes that it will consider necessary in its own products without effecting the essential characteristics of functionality and safety BURNERS GAS NORMAL PRESSURE INJECTOR DIAMETER TAPE BY PASS DIAMETER NOMINAL HEAT INPUT MJ h N DESCRIPTION KPa 1 100 mm 1 100 mm Max Min 1 RAPID Universal LPG 2 75 85 40 10 0 2 4 Natural 1 00 155 Adj...

Page 8: ...8 PRODUCT SERVICE PHONE NUMBER 1800 805 300 ...

Reviews: