9
Now carefully insert the inspection flap with the electronics on the other side and the
second inspection flap on the now open side and screw both inspection flaps tight
again with the previously unscrewed 3 screws per side.
Installation in the ceiling (ATTENTION: For recirculation operation, please note
the installation of the recirculation kit (p. 10/11) beforehand !!!)
Lift the ceiling fan into the cut-out provided until the retaining hooks fold outwards and
the ceiling fan hangs in the cut-out. Make sure that all four retaining hooks are folded
out. Now you can carefully let go of the ceiling fan. The ceiling fan should now protrude
slightly on the underside.
Fig. Insertion into the ceiling
After the ceiling fan has been hooked into the cut-out provided, carefully open the lower
front panel and turn the four fixing screws for the four retaining hooks clockwise until
the ceiling fan has been tightened to the ceiling. Make sure that all four screws for all
four retaining hooks are screwed tight.
Fig. Screw for fixing the retaining hooks through the underside
Fig. Final installation situation: