76
Level
Type
Description
INFO
PD inserted
Disk <slot> is inserted into system
WARNING
PD removed
Disk <slot> is removed from system
ERROR
HDD read error
Disk <slot> read block error
ERROR
HDD write error
Disk <slot> write block error
ERROR
HDD error
Disk <slot> is disabled
ERROR
HDD IO timeout
Disk <slot> gets no response
INFO
PD upgrade started
PD [<string>] starts upgrading firmware process.
INFO
PD upgrade finished
PD [<string>] finished upgrading firmware process.
WARNING
PD upgrade failed
PD [<string>] upgrade firmware failed.
INFO
PD RPS started L2L
Assign PD <slot> to replace PD <slot>.
INFO
PD RPS finished L2L
PD <slot> is replaced by PD <slot>.
ERROR
PD RPS failed L2L
Failed to replace PD <slot> with PD <slot>.
Hardware Events
Level
Type
Description
WARNING
ECC single
Single-bit ECC error is detected at <address>
ERROR
ECC multiple
Multi-bit ECC error is detected at <address>
INFO
ECC dimm
ECC memory is installed
INFO
ECC none
Non-ECC memory is installed
INFO
SCSI bus reset
Received SCSI Bus Reset event at the SCSI Bus <number>
ERROR
SCSI host error
SCSI Host allocation failed
ERROR
SATA enable device
fail
Failed to enable the SATA pci device
ERROR
SATA EDMA mem
fail
Failed to allocate memory for SATA EDMA
ERROR
SATA remap mem
fail
Failed to remap SATA memory io space
ERROR
SATA PRD mem fail
Failed to init SATA PRD memory manager
ERROR
SATA revision id fail
Failed to get SATA revision id
ERROR
SATA set reg fail
Failed to set SATA register
ERROR
SATA init fail
Core failed to initialize the SATA adapter
ERROR
SATA diag fail
SATA Adapter diagnostics failed
ERROR
Mode ID fail
SATA Mode ID failed
ERROR
SATA chip count
error
SATA Chip count error
INFO
SAS port reply error
SAS HBA port <number> reply terminated abnormally
INFO
SAS unknown port
reply error
SAS frontend reply terminated abnormally
INFO
FC port reply error
FC HBA port <number> reply terminated abnormally
INFO
FC unknown port
reply error
FC frontend reply terminated abnormally
INFO
Port linkup
The Port <number> link status is changed to Up.
INFO
Port linkdown
The Port<number> link status is changed to Down.
EMS Events
Level
Type
Description
INFO
Power install
Power (<string>) is installed
ERROR
Power absent
Power (<string>) is absent
INFO
Power restore
Power (<string>) is restored to work.
ERROR
Power fail
Power(<string>) is not functioning
WARNING
Power detect
PSU signal detection(<string>)
INFO
Fan restore
Fan (<string>) is restored to work.
ERROR
Fan fail
Fan (<string>) is not functioning