Suppl

220 V

Maxi
mum 

16 А

Powe

2 W

Weig
ht

100 g

Dime
nsion

83×83
×48 

Store 
settin

12 
mont

IP 
rating

IP21

Prote
ction 

II

Floor 
temp

TST02

Senso

2 m

Opera
ting 

from 
+5 °С 

Permi
ssible 

80 %

Maint
ained 

от +5 
°С до 

Facto

+28 

16 

Technical specifications

Summary of Contents for MCS 300

Page 1: ...Mobile Comfort System Technical Certificate User Manual Thermostat MCS 300 ...

Page 2: ...ion guide 9 Floor temperature sensor installation 9 Thermostat mounting 11 Thermostat installation 13 3 Technical specification 16 4 Your safety 17 5 Warranty obligations 18 Warranty Certificate 19 РЭА 00065 01П ИП РОСС RU AB87 B03861 Good for printing 16 07 2013 ...

Page 3: ...erature sensor included in the delivery set Remote control is carried out directly by the Wi Fi network of the smartphone or through the router There is a possibility of connecting several from 1 to 32 thermostats MCS 300 to your home network Thermostat MCS 300 is mounted into the wall in close proximity from the installation wire of the heating cable fig 3 Installation of a thermostat of other se...

Page 4: ...4 Introduction To begin the thermostat operation it is required to perform a few simple procedures 1 Install thermostat MCS 300 as described in the installation guide below ...

Page 5: ...2 Download the free app for your iPhone in AppStore by entering MCS 300 in search You may also find a reference to this app on the website www ses pro ru or on the QR code printed in the end of the manual on its cover ...

Page 6: ... In that case the thermostat acts as an access point Control would be possible only with one thermostat at a time Thermostat is ready for operation By running the application you will have full access to your warm floor system You may set operation modes heating temperature change all settings of your thermostat You can download the detailed manual on thermostat operation on our website http www s...

Page 7: ...y set of the thermostat MCS 300 includes 1 Thermostat MCS 300 1 pcs 2 Remote floor temperature sensor TST02 1 pcs 3 Technical Certificate Installation Manual 1 pcs 4 Packing box 1 pcs Fig 1 Outside view of MCS 300 thermostat ...

Page 8: ... shown on fig 6 there are LED signals and control buttons under it see fig 2 1 green indication of the power supply and presence of Wi Fi connection 2 red indication of heating turned on and sensor failure 3 default thermostat switch ON OFF control of the modes of the network connection 4 WPS setting WPS connection 1 3 2 4 ...

Page 9: ...Introduction 9 Fig 2 Thermostat MCS 300 with opened front cover 8 Controls and indication ...

Page 10: ...the same level as the heating cable between the loops at equal distances from them The other end of the corrugated tube with the sensor installation wire inside should be laid in the prepared groove chase in the floor and lead to the installation place of the thermostat or the junction box Excess of the tube and connection wire should be cut as applicable De energize the wiring system before you c...

Page 11: ...ls and materials necessary for installation 1 Corrugated plastic tube with the diameter at least 16 mm length of the tube depends on the place where the module will be installed 2 Standard plastic junction box 3 Flat blade and crosshead screwdrivers 4 Phase indicator to locate voltage wire ...

Page 12: ...nnecting procedures only under disconnected power supply Connect all wires to the device screw terminals If you have a two conductor supply network without an earthing conductor connection diagram is presented on fig 4 The cold lead screen wire of the heating section is connected to the neutral N conductor of the power network to terminal 5 If you have a three conductor supply network with a separ...

Page 13: ...core heating cable Fig 4 Connection diagram of heating section and mats to two conductor power network network earthing conductor network earthing conductor temperature sensor N L 220VA C external screw terminal temperature sensor N L 220VAC external screw terminal Single core heating cable Double core heating cable ...

Page 14: ...14 Installation guide Fig 5 Connection diagram of heating sections and mats to three conductor power network ...

Page 15: ...before installation Remove the front cover of the device To do so unlock the cover by inserting a flat blade screwdriver into the locking grooves located on both sides of the front cover fig 6 Remove the cover fig 7 Locking groove Locking groove Locking groove Fig 6 Front cover removing ...

Page 16: ...14 Installation guide Fig 7 Thermostat without cover ...

Page 17: ...s horizontal axis fig 8 Assembly of the thermostat is carried out in reverse order Carefully install the front cover of the thermostat back to its place pressing by hand till both clamps click Make sure that the front cover is securely fixed Front cover Fixing clamp Fixing clamp Junction box Fig 8 Assembly disassembly diagram of thermostat ...

Page 18: ...ndard stopper plugs of some manufacturers of electric equipment They may be installed instead of the MCS 300 frame and attached to the terminal box by screws To remove the frame of the device press the four fixing clamps located on the upper and bottom sides of the thermostat with the flat blade screwdriver fig 9 pulling the frame out Clamps Clamps Fig 9 Dismantling the removable frame ...

Page 19: ...ST AT MCS Suppl y 220 V Maxi mum 16 А Powe r 2 W Weig ht 100 g Dime nsion 83 83 48 Store settin 12 mont IP rating IP21 Prote ction II Floor temp TST02 Senso r 2 m Opera ting from 5 С Permi ssible 80 Maint ained от 5 С до Facto 28 16 Technical specifications ...

Page 20: ... mechanicals impacts shocks falls and etc Do not expose the thermostat to water Do not expose any parts of the thermostat to any liquids containing acids alkalis oils and etc Use dry soft pieces of clothes to clean the thermostat While operating and maintaining it is necessary to follow the require ments of GOST 12 3 019 80 Regulations for Operation of Consumer Elec trical Installations and Safety...

Page 21: ...Your safety 17 ...

Page 22: ...ns on installation and operation are followed The warranty does not cover any mechanical damage of the thermostats or defects caused by inadequate installation connection or operation of the product To get warranty obligation fulfilled it is obligatory to submit a filled out warranty certificate indicating the name of the product the name of the place where the product was bought the name of the S...

Page 23: ...18 Warranty obligations ...

Page 24: ...300 Date of manufacture Has passed acceptance tests and is declared acceptable for service QCD stamp Seller Date of sale Seller s stamp Manufacturer I WARM ELECTRIC HEATING SHENZHEN CO LTD 4 F South Office Building Dacheng Industrial Park ...

Page 25: ...Jihua Road East Buji Shenzhen China 518112 Warranty certificate 19 ...