background image

MAJ   :   16.09.11   

   

       

   

   

THERMOSTAT 
I WARM 750 
 
 
OPERATION MANUAL 

 
 
 

1. FUNCTION

 

The  thermostat  is  designed  for  indoor  electrical  underfloor  heating  systems  (e.g.  with  electrical  heating  mats  as  well  as 
electrical heating sections) or other electrical heating systems and devices.

 

It keeps the temperature you have set based on data received from the floor mounted temperature sensor.

 

 

2. TECHNICAL INFORMATION

 

   

 

Supply voltage

   

230 VAC, 50-60 Hz 

Maximum current

   

16A 

Temperature range

   

+5°C to +45°C 

Weight

   

150g (including sensor) 

Dimensions

   

80 x 80 x 58 mm 

Floor temperature sensor

   

NTC 6.8 kOhm 

Sensor cable lenght

   

2m

   

 

3. CONNECTING DIAGRAM

 

The temperature sensor is connected to terminal 1 and 2, the supply voltage to terminals 5 and 6, the neutral line to 5 and the 
phase (detected by an indicator) to 6. 

 

The  cold  leads  of  the  heating  system  are  connected  to      the 
contacts  3  and  4,  the  screen  to  the  grounding    conductor  by 
means  of an external terminal (included).

 

The  cold  leads  of  the  heating  system  are  connected      to   
the contacts 3 and 4, the screen to the grounding  conductor 
by  means  of an external terminal (included).

 

 
 
 
 
 
 
 
 

 

 

4. INSTALLATION AND OPERATION

 

Install  and  connect  the  thermostat  after  the  installation    and    testing  of  the  underfloor  heating  system  (or  any  other  heating 
system).

 

The thermostat is equipped with a switch, a temperature control knob and a

 

LED indicator light.

 

The thermostat is designed for installation in a wall mounting box according to

 

DIN 4937-1 (not included in the delivery set).

 

Moving the switch to the upper position (1) turns the thermostat on, moving it to the down position (0) turns the device off. Turning the 
temperature control knob clockwise  will  increase  the  temperature,  turning  it  counter-clockwise  will decrease it. As soon as the 
LED is lighted, the heating system is energized. 
 

PREPARATION FOR INSTALLATION 

   

1. 

Prepare a recess in the wall suitable for the wall mounting box.

 

2. 

Route the power supply cable, the cold leads and the temperature sensor

   

cable to the wall mounting box. The sensor 

cable has                to be in a corrugated tube in order to facilitate if it’s necessary to exchange it in future.

 

3. 

The switch of the thermostat has to be in position (0).

 

4. 

Perform all connections (according to part 3).

 

5. 

Take the temperature control knob carefully off by using a screwdriver.

 

6. 

Take off the front cover of the thermostat. Therefore use a small flat-head screwdriver to press the locks located on the 
upper and lower side of the front cover and pull out the cover. Remove the front cover and the frame.

 

7. 

Place the device in the wall mounting box and fix it with screws.

 

8. 

Assemble the thermostat acting in reverse order. Install the frame carefully ensuring that it closely fits to the device’s case. 
Then place the front cover to the frame and press it carefully ensuring that the locks are snapped in.

 

9. 

Turn the regulator clockwise until the end position by means of a screwdriver.

 

Now place the knob so that the marking points 

to the LED and fix the knob.

 

10.  To turn the thermostat on, ensure that the control knob is turned clockwise until the end position and move the switch to 

position (1). Now the LED light shows  that  the  system  is  energized  (heating).  After  reaching  the  comfort heating level, 