5. Secondary lock installation
5-1.Secondary lock part
①
After terminal insertion is complete, close the secondary lock part.
You will hear audible click when the secondary lock part is engaged properly.
(The secondary lock part has two engaging portions. Press down to make sure both portions are engaged)
②
Check that the secondary lock part is closed in compretely, i.e. aligned with the bottom surface of the housing.
When the secondary lock part cannot be closed in completely, do not close forcefully. Check that the terminals
are inserted correctly and sufficiently,and repeat the insertion procedure in 4. Insert all the
terminals properly, and push the secondary lock part until audible click is heard.
③
When terminal(s) is/are insufficiently inserted as shown in Fig.29, the secondary lock part cannot be closed.
Insert the terminal(s) completely, and close the secondary lock part again.
Fig 28. Installation of the secondary lock part
Close
Fig.29. Insufficient the secondary lock part engagement
Before
After
Engaging portion
Engaging portion
The secondary lock part cannot be closed
Secondary lock part
Table5. PART NO.: FEMALE HOUSING
No. of
Poles
PART NO.
3 ISH CONNECTOR 3P FEMALE HOUSING
V0013-91003-211
3 ISHV CONNECTOR 3P FEMALE HOUSING
V0037-91003-211
NAME