ISH & ISHV & ISHVS CONNECTOR Instruction Manual
Document No.
HDM-0002
27
/
29
Confidential C
11-2. Arrangement of Wires
①
When arranging the wires horizontally, to avoid excessive stress to the sidewalls and female terminals,
and the female terminal leaning in the core hole, please keep the wires straight (at least 15mm) from connector as shown in Fig.56
②
Once straight portion is secured, arrange the wires with adequately large R.
Reference
:
Probe pin position on female housing
①
Female housing - single row
②
Female housing - double row
Fig 56. Arrangement of wires
15
㎜
MIN.
Straight portion
Distance between
probe pin
Housing thickness
Distance between probe pin insert hole bottom surface and female terminal
Distance between female housing bottom surface and top surface of probe pin
Distance between female housing bottom surface and top surface of probe pin
Distance between probe pin insert hole bottom surface and female terminal
Housing thickness