background image

 

4

OSD SET UP MENU 

The menu structure below is for the VN-856 high-resolution color and VN-856DN day/night cameras. The 

menu for the VN-856WDR follows. Use the buttons on the rear panel of the camera to access the Menu 

system and the up/down and left/right buttons to navigate within the menu selections. 

 

Setup Menu 

Function 

Summary 

 

LENS 

 

MANUAL or DC VIDEO 

Select the type of  the lens  used on the camera. If DC is 
selected, select brightness level (1-70). DC is default. 

SHUTTER 

ESC

MANUAL

FLK 

MANUAL: 1/60(50) ~  1/120,000 sec; x2 -x128 
ESC: Brightness level (1-70) (only available with Manual
Lens setting)   

WHITE 
BALANCE 

 

ATW

AWC

MANUAL 

ATW:  1,800  ~ 10,500°K 

AWC: ONE PUSH 

MANUAL: RED/BLUE  adjustable  (0-256).   
ATW is default. 

BACKLIGHT 

OFF

LOW

MIDDLE

HIGH

Backlight compensation. OFF is default. 

AGC 

OFF

LOW

MIDDLE

HIGH

Brightness can  be adjusted (1~70). LOW is default. 

DNR (Digital 
Noise Reduction)

OFF

LOW

MIDDLE

HIGH 

DNR does not operate when AGC is turned off.  
LOW is default.

 

SENS-UP 

 

OFF

AUTO 

Adjusts sensitivity level. When  AGC  is turned 
off, SENS-UP does not operate. AUTO is default. 

SPECIAL 

See menus below 

 

EXIT 

 

Save all the settings and  then  exit 

 

Special Menu 

Function 

Summary 

 

CAMERA ID 

OFF

ON 

Maximum length for the name display is 15 letters. 
English uppercase or lowercase letters, numerals 0~9, -, 
null 
OFF is default.

 

 
 

COLOR 

 

 
 

AUTO

ON 

AUTO mode:  Day/Night electronically  changes  to 
the appropriate  mode: 

-Daytime: COLOR  mode 
-Night-time: BW  mode 

ON mode:  Always COLOR  mode 
On is default for VN-856;   
AUTO is default for VN-856DN. 

SYNC INT 

Auto Detection 

 

MOTION 
DETECTION 

 

OFF

ON 

ON mode:  AREA (4 programmable zones)/SIZE 
"MOTION DETECTED"  appears on  the screen 
when movement is detected. OFF is default.

PRIVACY 

OFF

ON 

ON mode:  AREA (4 programmable zones)/SIZE/TONE
OFF is default 

MIRROR 

OFF

ON

Set  a horizontal  image inversion. OFF is default 

SHARPNESS 

OFF

ON

The available range of level is  0 ~  31. ON is default 

 

RESET 

 

Returns to the level  which  was  set  by the 
manufacturer for shipment 

 

RETURN 

 

Saves the SPECIAL  menu  s e t t i n g s   and  then 
returns to the SETUP menu 

 

 

XX181-10-02 Rev 110 VN-856V5 IP Camera 

 

Summary of Contents for VN-856V5

Page 1: ...s purpose Warning To prevent fire or shock hazard do not expose the unit to rain or moisture Copyright 2010 Vicon Industries Inc All rights reserved Product specifications subject to change without no...

Page 2: ......

Page 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Page 4: ......

Page 5: ...Introduction 1 Connectors and Controls 2 OSD Menu for VN 856 4 ViconNet Configuration 12 Shipping Instructions 21 Coaxial Cable Recommendations 22 Twisted Pair Cable 23 Network Cable 24 Technical Inf...

Page 6: ...re they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent...

Page 7: ...The VN 856 delivers up to 30 fps This IP camera series includes a high resolution color model a day night version and a model that offers Wide Dynamic Range WDR All versions can be powered by 24 VAC o...

Page 8: ...should be used for the cable for 24 VAC input terminal 3 ALARM Alarm Input and AUDIO Microphone This terminal block input provides 1 alarm and 1 audio input to the camera ALARM Alarm Output can be de...

Page 9: ...and power supply If the lens is motorized it must also be connected to a lens control 2 Position the camera 25 50 feet 8 16 meters from a flat vertical surface suitable for focusing A newspaper works...

Page 10: ...is turnedoff LOW is default SENS UP OFF AUTO Adjusts sensitivity level When AGC is turned off SENS UP doesnot operate AUTO is default SPECIAL See menus below EXIT Save all the settings and then exit S...

Page 11: ...BLC WDR LIMIT LOW MIDDLE HIGH range of 1 100 BLC TOP BOTTOM LEFT RIGHT OFF TOP BOTTOM 0 132 level selectable LEFT RIGHT 0 15 level selectable LEVEL LOW MIDDLE HIGH OFF is default DNR Digital Noise Re...

Page 12: ...RAY TRANSP 0 3 Level selectable RETURN OFF is default DIS ON OFF OFF ON OFF is default COMM ADJ for factory settings only CAM ID BAUDRATE UART MODE RET PKT DISP CAM ID CAM ID ID selectable 0 255 0 is...

Page 13: ...L 4 9 EXIT 1 LENS DC4 2 SHUTTER 3 WHITE BAL 4 BACKLIGHT 5 AGC 6 DNR 7 SENS UP 8 SPECIAL 9 EXIT 1 LENS 2 SHUTTER ESC4 3 WHITE BAL 4 BACKLIGHT 5 AGC 6 DNR 7 SENS UP 8 SPECIAL 9 EXIT Shutter provides cho...

Page 14: ...ettings are needed using the same method White Balance can be directly adjusted by user in Manual mode The value of Red and Blue can be controlled 0 256 Considering the change of color select proper v...

Page 15: ...XIT DNR Digital Noise Reduction significantly reduces the amount of low illuminance noise DNR mode can be setup as HIGH MIDDLE LOW OFF AGC must be turned ON for DNR to operate SENS UP Sens Up mode con...

Page 16: ...N or OFF When ON the AREA 4 programmable zones and the SIZE of the zones can be set The words MOTION DETECTED appears on screen when movement is detected in the defined zone s Privacy Privacy can be s...

Page 17: ...857WDR has a similar menu structure as the color and day night versions Additionally there is a menu to select WDR Wide Dynamic Range ON or OFF WITH WDR OFF WITH WDR ON XX181 10 02 Rev 110 VN 856V5 I...

Page 18: ...e minimum requirements is running the ViconNet application version 5 VNSetup and has the proper PTZ camera driver The VNSetup is found on the included CD under software IP Camera Setup Refer to approp...

Page 19: ...13 XX181 10 02 Rev 110 VN 856V5 IP Camera...

Page 20: ...e desktop for future use 1 Make sure the MAC address and password of the camera is available Use MAC Address log provided 2 Verify that the camera is physically connected to the configuring workstatio...

Page 21: ...e This is correct for BIOS from version 1 0 10 86 and later ViconNet version 3 3 Password authentication There are two authentication options You can either authenticate a specific unit by entering it...

Page 22: ...vel on a scale of 0 4 where 4 is most information Note The Apply button must be pressed for changes to take effect Note Verify all IP addressing parameters with your IT administrator Note In order for...

Page 23: ...nstall TAB The Install TAB allows the user to install upgrade newer versions Install Info Tab The Info TAB displays the selected IP product general information Info XX181 10 02 Rev 110 VN 856V5 IP Cam...

Page 24: ...ng of application is disabled The Disable load button allows the pausing of the application load in case of software issues while still permitting communication via VNSetup the Enable load button resu...

Page 25: ...ion server or recorder are available as follows A network settings screen is used to modify the camera s IP parameters This allows great flexibility in network setup Note This setup can be performed f...

Page 26: ...ViconNet system through a workstation recorder or server 1 System macros can be configured to view and record the camera s video In addition within macros alarms can be sent and remote macros triggere...

Page 27: ...y Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit...

Page 28: ...ance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables othe...

Page 29: ...or RS 422 RS485 applications Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The ma...

Page 30: ...ations Choose a Belden cable type by referring to the characteristics listed below The Table below should be used as a guideline when cables other than Belden are used Materials and construction must...

Page 31: ...oE VN 856 5 8 W max VN 856DN 6 5 W max VN 856WDR 6 4 W max 0 3 btu min 0 09 kg cal min nominal Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage of...

Page 32: ...MECHANICAL Signal to Noise Ratio White Balance Video Signal Output Synchronization In Gain Control Output for Autoiris External Controls Connectors Better than 52 dB Automatic 1 0 V p p VBS 75 ohms co...

Page 33: ...t showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair S...

Page 34: ...pe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office...

Reviews: