page 9
2.4. Network Configuration
In principle, the OABR Multi-Media-Switch acts as a standard switch in a network. This means:
a) for the participation of the PC via the OABR switch on this network, the PC must have the same
subnet mask as well as a valid IP address. b) Please make sure that no IP address is assigned
twice. Sniffing in the network (e.g., via Wireshark) requires no special setting on the PC.
2.5. Pinning Tyco MQS
Explanation of the connections:
• HighSpeed CAN High/Low
Connection of the Higspeed CAN. Please pay attention
to the correct termination of your CAN bus.
• U_Bat
Power supply 12V
• GND
Ground
• ETH_ON
The port is bi-directional. The OABR-Switch
can be configured that in case of a positive signal level
the devices wakes up. The pulse width can be
configured. Additionally, over the GUI, a trigger signal
can be sent. The signal level is GND (default) until
U_BAT. In mode „Always On“, the input trigger signal is
ignored, the device is always active.
• OABR +/-
OABR connectors
• OABR Shield
On this pins - if necessaary - a cable shield can be
connected. The Shield is connected to the housing
via a RC-Filter.
High Speed CAN - Low 18 9 High Speed CAN - High
U_BAT 17 8 GND
16 7
GND
15 6
OABR Port2- 14 5
OABR Port2+ 13 4
OABR Shield 12 3 OABR Shield
OABR Port1- 11 2
OABR Port1+ 10 1
ETH_ON
Summary of Contents for 2-Port OABR Multi-Media-Switch