COBALT Pro
™
Exposed Flush Valve
Standard Operations
101819 / 101673
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents
page 4
Rev 081723
ADJUSTABLE PARAMETERS
Range
Adjusts the maximum range used to detect a user. The range can be adjusted from 6-54 inches.
Exit Time
Adjusts the amount of time an object must not be detected before the valve considers the user to have exited.
The range can be adjusted from 0-15 seconds.
Water Savings
Adjusts the water volume savings in percent.
Base Volume
Adjusts the base volume.
Adjusted by first pressing the Profile Selection button, and then adjusting using the water savings dial.
Due to display limitations volumes are truncated on the display.
Fixture Type
Selectable Volume
Displayed Value
Urinal
0.125, 0.25, 0.5, 1.0 gallons
0.1, 0.2, 0.5, 1.0
Water Closet
1.1, 1.28, 1.6, 2.4, 3.5 gallons
1.1, 1.2, 1.6, 2.4, 3.5
Redetect Time
Adjusts the amount of time a user must be out of range before another user can be detected. The range can be adjusted
from 0-60 seconds.