COBALT Pro
™
Exposed Flush Valve
Standard Operations
101819 / 101673
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents
FACTORY RESET
A factory reset is performed by:
1. Power off the interface box.
2. Press and hold the activate button in the interface box.
3. Restore power, while still holding the activate button.
4. Release the activate button after the green LED blinks 4 times. The factory reset is finished.
MAINTENANCE MODE
If the cover is removed the valve will go into Maintenance Mode which allows additional actions. Auto Activations are unavailable
in Maintenance Mode. While in Maintenance Mode a solid green LED indicates that an object is detected. Maintenance Mode
times out and returns to User Mode after 30 minutes. Maintenance Mode may be reentered by pushing a tac switch on the control
module.
BUTTONS
There are 4 buttons on the control module. From left to right they are:
1. Auto-Range
2. Profile Selection
3. Activate
4. Activation Count Reset
Auto-Range
Activated by holding the Auto-Range button for 3 seconds. When triggered a 5-second countdown will occur with the green LED
blinking once each second.
During Auto-Range the green LED will be solid.
After Auto-Range is complete the green LED will blink 3 times.
If during Auto-Range, no object is detected or there is an error with the auto-range process (such as IR sensor malfunctioning)
the value will be set to the default range.
Profile Selection
Profiles change the water savings value. Pressing the Profile Selection button will display the current profile. Pressing the Profile
Selection button again will cycle through the pre-configured profiles. There are 3 profiles.
1. Indicated by blue and red LEDs. 10% water savings.
2. Indicated by blue LEDs. 5% water savings.
3. (Default) Indicated by blue and green LEDs. 0% water savings.
To load a new profile press and hold the Profile Selection button for 3 seconds when the desired profile is indicated.
The LEDs will flash to show the profile has changed.
After 5 seconds profile mode will end, and the LEDs will clear.
page 2