COBALT Pro

 Exposed Flush Valve  

Standard Operations

101819 / 101673

I-CON  Systems,  Inc.,  for  product  support  call  1-866-730-7192  or  visit  us  online  at  support.i-con.com                           

One or more products contained herein are protected by U.S. Patent with other undergoing the patent process www.i-con.com/patents

page 3

Rev 081723

Activate 

The activate button on the control module performs a standard flush indicated by a blue LED blink.

Activation Count Reset 

The activation count is reset by holding the Activation Count Reset button for 5 seconds. 

 

The red LEDs on the device will rapidly blink when the reset has occurred.

COBALT® PROGRAMMER

To take full advantage of features available in Maintenance Mode a COBALT® Programmer is required. 

 

The COBALT® Programmer is used to read the current activation count, alerts, and make changes to parameters. 

The COBALT® Programmer is sold separately.

When plugged into the valve a round-robin display will begin. If an adjustment is made, the displayed 

 

setting and respective LED will blink, and the round-robin will restart.

ROUND-ROBIN DISPLAY

When the Round-Robin Display begins, it will cycle through the alert codes, activation count, and current values of adjustable 

parameters.

ALERT CODES DISPLAY

Alert codes can be seen on the COBALT® Programmer. Additionally, the valve will flash a red LED every 10 seconds when 

 

an alert is present.

Indicated by AL and then the code number in the COBALT® Programmer Round-Robin Display.

 

Code 1 Device Battery End-of-Life

 

The battery voltage has dropped below 5V. Activations will be disabled. The valve will flash the red LED rapidly.

 

Code 2 Activation Count Threshold Reached 

 

250,000 activations have been reached since the last reset, indicating that the valve should be rebuilt. 

 

Code 4 Obstruction 

 

An object has remained locked on for 30 minutes. Auto Activation is disabled. To exit obstruction nothing 

 

must be detected for 5 seconds. 

 

Code 6 Disconnected or faulty Pressure/Temperature Sensor 

 

The Pressure/Temperature sensor must be plugged in or replaced.

 

Code 7 Low Device Battery 

 

The battery voltage has dropped below 6V.

ACTIVATION COUNT

The current number of activations since the last activation count reset.

Indicated by AC and then the number of activations scrolling from right to left on the COBALT® Programmer.

The activation count is saved to memory at certain intervals depending on the total number of activations. For the first 100 

activations it saves every activation. From 100 to 1000 activations, it saves every 10 activations. For 1000+ activations it saves every 

100 activations. For example, if the device is powered off at 215 activations, when powered back on it will report 210 activations.