N100
plus
Inverter RS485 Interface Instruction Manual
2.3
Frequency Command
2.3.1
A prior condition
(1) Communication number :
01
(Inverter address 1)
(2) Command
:
06 (Setting
request)
(3) Parameter
:
0004
2.3.2
Example 6 – Frequency Command (In case of 60Hz)
(1) Transmit Data (In case of 60.00Hz)
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600041770C61F
01 06 00 04 17
70 C6 1F
Data Description
1x16
3
+ 7x16
2
+ 7x16
1
+ 0x16
0
= 6000 (Communication Data)
Î
divide by 100
Î
60.00Hz (Parameter value)
(2) Response
Data
Response (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600041770C61F
01 06 00 04 17
70 C6 1F
2.3.3
Example 7 – Frequency Command (In case of 50Hz)
(1) Transmit Data (In case of 50.00Hz)
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600041388C55D
01 06 00 04 13 88 C5 5D
Data Description
1x16
3
+ 3x16
2
+ 8x16
1
+ 8x16
0
= 5000 (Communication Data)
Î
divide by 100
Î
50.00Hz (Parameter value)
(2) Response
Data
Response (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600041388C55D
01 06 00 04 13
88 C5 5D
N100_Inverter RS485 Interface Manual(English).doc