N100
plus
Inverter RS485 Interface Instruction Manual
2.1.3
Example 2 – Output frequency (Function code : F01)
(1) Transmit
Data
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Parameter
Count
CRC 16
Hi Lo
010302010001D472
01 03 02 01 00 01 D4 72
(2) Response Data (In case of F01 = 60.0Hz)
Response (7Byte)
Com.
Num.
Com-
mand
Byte
Q’ty
Data
CRC 16
Hi Lo
0103021770B650 01 03 02 17
70 B6 50
Data Description
1x16
3
+ 7x16
2
+ 7x16
1
+ 0x16
0
= 6000(Communication Data)
Î
divide by 100
Î
60.00Hz (Parameter value)
(3) Response Data (In case of F01 = 50.00Hz)
Response (7Byte)
Com.
Num.
Com-
mand
Byte
Q’ty
Data
CRC 16
Hi Lo
0103021388B512 01 03 02 13
88 B5 12
Data Description
1x16
3
+ 3x16
2
+ 8x16
1
+ 8x16
0
= 5000(Communication Data)
Î
divide by 100
Î
50.00Hz (Parameter value)
2.1.4
Example 3 – Acceleration time (Function code : F02)
(1) Transmit
Data
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Parameter
Count
CRC 16
Hi Lo
010302010001D472
01 03 02 02 00 01 24 72
(2) Response Data (In case of F02 = 10.0sec)
Response (7Byte)
Com.
Num.
Com-
mand
Byte
Q’ty
Data
CRC 16
Hi Lo
0103020064B9AF 01 03 02 00
64 B9 AF
Data Description
0x16
3
+ 0x16
2
+ 6x16
1
+ 4x16
0
= 100(Communication Data)
Î
divide by 10
Î
10.0sec (Parameter value)