INSTALLATION & OPERATION MANUAL
L500 Series
- 20 -
• The Automatic Drain Valve allows condensed
water in the intercooler to drain when the
engine is a idle or is stopped.
AUTOMATIC DRAIN VALVE
Snap-Ring
Flanger
Spring
CHECKING AUTOMATIC DRAIN VALVE
• Stop the engine and remove the Automatic
Drain Valve from the intercooler.
• Removing procedure:
• Remove the Snap Ring
①
• Remove the Plunger
②
• Remove the Spring
③
• Clean the inside of the Automatic Drain
Valve with a cloth or by brushing
• Installation is in the reverse order of removal.
• Put the Automatic Drain Valve on a flat surface.
Make sure that Snap Ring
①
and plunger
②
are in contact.
• If there is more than a 2mm gap between the
Snap Ring
①
, and the Plunger
②
replace the
spring.
Condensate water Emission from intercooler.
Replace a part
Normal