13
4.1 STARTING YOUR GENERATOR
WARNING!
BEFORE USING THE GENERATOR, A GROUND WIRE MUST BE CONNECTED
TO THE GROUND TERMINAL. THE GROUND TERMINAL IS LOCATED ON
THE FRONT PANEL. BEFORE USING THE GROUND TERMINAL CONSULT A
QUALIFIED ELECTRICIAN.
NOTE
Before starting the engine disconnect all devices from the outlets on the
front panel.
Return the starter grip slowly by hand, do not let it snap back.
Do not pull out the choke knob when the engine is hot or ambient air
temperature is high
1.
Rotate the fuel cap vent lever to ON.
2.
Rotate the fuel valve to the OPEN position.
3.
Turn the power switch to the ON position.
4.
If the engine is cold pull the choke lever fully out.
5.
Pull the starter slowly until you feel it engage then pull quickly. Repeat until
the generator starts.
6.
When the engine warms up push the choke fully in. The choke is used to
provide the proper air-fuel mixture when the engine is cold.
OPEN
CLOSED
1
2
3
4
5
6