16
5.2 DC APPLICATIONS
The DC receptacle may be used for charging 12V batteries
only
. In DC operation,
turn EcoMode OFF.
NOTE
The DC receptacle can be used while the AC power is in use. If used at
the same time, be sure not to exceed the total power for AC and DC.
(AC: 1600W, DC: 5A)
Motor vehicles require more than their rated wattage when starting.
Connecting the charging cable:
1.
If connecting to a vehicle battery, disconnect the vehicle battery ground
cable from the negative (-) battery terminals.
2.
Connect the DC outlet to the battery terminals using the included charging
cable. Connect red lead to positive (+) battery terminal and black lead to
negative (-) battery terminal.
3.
Turn EcoMode OFF, and start the generator.
NOTE
Do
not
start the vehicle engine when the generator is still connected to
the battery, this will damage the generator.
System floating for DC output.
Disconnecting the charging cable:
1.
Turn off the generator.
2.
Disconnect the black lead from the negative (-) battery terminal, and the red
lead from the positive (+) battery terminal.
3.
Reconnect the vehicle battery ground cable.
HY