HY2000si and HY2800sei User Manual

PROBLEM

SYMPTOMS

CORRECTION

Generator 

will not 

start

Generator 
will not start

1.  The on/off switch is in the “Off” position. 

Switch  to  “On.”                                                                                                                        

2.  The  engine  is  out  of  gasoline.                                                                               
3.  Engine choke is in wrong position. Adjust 

choke lever according to instructions on 
page 12.                                                                                      

4.  Fouled spark plug, replace with equal or 

greater quality plug. Refer to page 27 in your 
user’s manual for a complete list of spark 
plug  compatibility  codes.                                                                                                         

5.  Insufficient  oil,  add  more  oil.                                                                            
6.  Clogged fuel line, inspect gas tank for 

debris.

High resis-
tance when 
pulling recoil 
starter.

1. 

The engine does not have enough oil - 
add oil.                                                               

2. 

Air filter element obstructed by debris. 
Clean according to user manual instruc-
tions on page 18.                              

Difficulty 
starting

Engine re-
quires many 
attempts to 
start

1. 

Disconnect load before starting.               

2. 

Incorrect oil being used. Please refer to the 
oil usage chart on page 27 in your user’s 
manual.                                                                                                         

3. 

Fouled spark plug, replace with equal or 
greater quality plug. Refer to page 27 in 
your user’s manual for a complete list of 
spark plug compatibility codes.

Generator 
does not 
produce 
power

No indicator 
lights or 
display on 
front panel

1.  Generator circuit breaker off or tripped 
2.  Remove all loads, reset breaker, and check 

device for defects. Do not exceed generator 
rating.

Summary of Contents for HY2000sei

Page 1: ......

Page 2: ...HY2000 2800_UG_EN 2014 MIDLAND POWER INC ...

Page 3: ...n in this publication is based on the latest product information available at the time of approval for printing No part of this publication may be reproduced without written permission If a problem should arise please contact us by using the contact information at the end of this manual It is important that this manual be read and fully understood before operating the generator set Failure to do s...

Page 4: ...tion Inspection Fuel Level Check Air Filter Check Initial Startup Operating Your Generator Shutting Off Your Generator Maintenance Troubleshooting Specifications Warranty Glossary Transfer of Ownership and Warranty Card Warranty Registration Card 5 6 7 8 9 10 11 13 18 19 24 28 30 33 35 37 ...

Page 5: ...se they can ignite OPERATING INSTRUCTIONS Operate the generator according to instructions for safe and depend able service Always perform a pre operation inspection before starting the engine Properly clean and maintain the equipment Make sure to read and understand all warning labels Gasoline is a highly flammable and explosive liquid Make sure to refuel in a well ventilated area with the engine ...

Page 6: ...upply should be done by a professional electrical technician Improper con nections may lead to a fire hazard or damages to the generator set MAINTENANCE SAFETY After any maintenance is performed wash your body immediately us ing soap and clean water Repeated exposure to lubricant may cause skin irritation Do not clean the filter sponge with flammable fluids such as gasoline or explosion may occur ...

Page 7: ... Moisture can damage the generator and can lead to an electric shock IDENTIFICATION OF COMPONENTS Choke Lever Primer Bul b Fuel Valve Battery Cover Rear Cover Maintenance Cover Control Panel Fuel Cap Cover Top Maintenance Cover Starter Grip Engine Switch ECON Switch 12V DC DC Reset 12V DC Engine Switch USB 5V Charging Port AC Circuit Breakers AC Circuit Breaker Low Oil Warning Light Overload Warni...

Page 8: ...temperature in your area 1 Loosen the cover screws and remove the maintenance cover refer to fig 2 Remove the oil filler cap and wipe the dipstick clean refer to fig Check the oil level by inserting the dipstick into the filler neck without rotating it 3 If the level is low fill to the upper limit of the oil filler neck with the recommended oil 4 Reinstall the maintenance cover and tighten the cov...

Page 9: ...f generator gas tank 2 Refill the fuel tank if the level is low Refuel carefully to avoid spilling fuel Do no fill above the upper limit mark Refer to Fig CAUTION Gasoline is highly flammable and explosive Keep the engine away from heat spark the open flame Refuel in a well ventilated area with the engine stopped Only handle fuel outdoors Wipe up spills immediately Avoid getting dirt dust or water...

Page 10: ...aminants such as dust and dirt being drawn through the carburetor into the engine 1 Remove air filter cover and sponge 2 Inspect filter sponge for dirt and debris 3 Clean filter sponge by soaking in gasoline ring out before reinstalling 4 Replace air filter every 24 months or when necessary Screws Maintenance Cover Air Filter Sponge Air Filter Cover ...

Page 11: ...emove the Battery Access Panel from the unit by unscrewing the screw at the top and releasing the panel 2 Connect the Battery HY2800 ONLY locate and connect the loose connectors from the battery wiring harness and the main wiring harness The battery is 3 HY2800 ONLY Re install the Battery Access Panel onto the unit Ensure the screw is fastened properly 4 Remove the main engine access panel from th...

Page 12: ...all the Oil Dipstick and fasten tightly Wipe away any excess oil For best results drain and refill the engine oil after the first 20 hrs of use and every 50 hrs thereafter Do not remove the Oil Dipstick when the engine is warm from prior use 8 Re install the Engine Access Panel onto the unit ensur ing that all 2 screws are fastened properly 9 Remove the fuel cap exposing the fuel tank Be sure not ...

Page 13: ...eave the choke in the Open position if the generator is still warm from recent use or if the air temperature is higher than 50 F 10 C 4 Locate and press primer bulb 15 20 times to move fuel through the lines and into the engine Note This step is only necessary when the engine is cold 20X OPERATING YOUR GENERATOR Before using generator a ground wire must be connected to the ground terminal The Grou...

Page 14: ... engine starts Do not release the pull cord at the end of a pull this will damage the recoil assembly Bring the pull handle back down to the unit by hand 6 Once the generator has started wait at least 30 seconds for it to warm up and then you may slowly open the choke lever until it is fully open or OFF 7 Connect all of your devices to the generator 8 Turn EcoMode switch to On This will reduce the...

Page 15: ...is intended for Be sure to use properly isolated cable when an extension cable is required Limit length of extension cables to 60 m for cables of 1 5 mm wire thickness and 100 m for cables of 2 5 mm wire thickness Keep the generator away from other electric cables or wires such as a distribution network The DC receptacle can be used while the AC power is in use If you use both at the same time be ...

Page 16: ... service life of the generator If the oil level falls below a safe limit the low oil indicator light Red comes on and the engine will be automatically stopped If the engine stops or the low oil indicator light comes on when you pull the starter grip check the engine oil level before trouble shooting in other areas Refer to Fig A hot engine will not start if there is too much gasoline in the cylind...

Page 17: ...tive battery terminal and negative black terminal of the charging wire to the negative battery terminal 3 Turn the start switch to the ON position 4 Set the DC breaker switch to ON position refer to fig 5 Start the generator NOTICE The DC socket is only used for charging a 12V battery When using the DC socket turn the ECON switch to the OFF position WARNING The battery gives off explosive gases ke...

Page 18: ...n an emergency turn the engine switch OFF Always connect the ground terminal at the front panel to the ground earth to prevent electrical shock 1 Disconnect all devices from the generator 2 Turn EcoMode switch to Off 3 Turn Power switch to Off 4 Close the fuel valve by turning it to Off ...

Page 19: ... Contact customer service for replacement parts Some of these maintenance techniques can be dangerous and should be performed by a qualified technician To ensure long lasting durability and performance be sure to inspect and main tain your generator based on the schedule below ITEM ACTION EACH USE 1 MONTH 20 HRS 4 MONTHS 50 HRS 6 MONTHS 100 HRS YEARLY 200 HRS ENGINE OIL Check Level Change AIR FILT...

Page 20: ...ean the sponge Clean air filter sponge in warm soapy water or non flammable detergent Allow to dry before reinserting into generator Dip sponge in clean engine oil and squeeze out all excess oil The engine will produce excess smoke if too much oil is left in the filter Wipe dirt off the air filter cover using a moist rag CHANGING THE ENGINE OIL 1 Set the start switch to the STOP position and make ...

Page 21: ...ING Make sure the start switch is in the STOP position before draining Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the trash or pour it on the ground Do not use gasoline for cleaning since it is flammable and explosive under certain conditions L L 2...

Page 22: ... Remove the ignition coil refer to fig 3 Clean any dirt and debris around the spark plug base 4 Use a wrench to remove the spark plug refer to fig 5 Visually inspect the spark plug Clean the spark plug with a brush if it is to be reused 6 The spark plug clearance gap should be between 0 7 mm 0 8 mm 0 028 to 0 03 refer to fig Screw Top maintenance cover Ignition Coil Spark Plug Wrench Ignition Coil...

Page 23: ...tion with the start switch in the STOP position 4 Do not drop or strike the generator when transporting 5 Do not place heavy objects on the generator WARNING Gasoline is extremely flammable and explosive under certain conditions Do not smoke or allow flames or sparks in the area STORAGE PROCEDURE 1 Drain fuel remove gas tank cap remove fuel filter and syphon fuel into an appropriate gasoline conta...

Page 24: ...ance then return the starter grip gently This closes the valves so moisture cannot enter TROUBLESHOOTING If the generator still does not start have an authorized Hyundai repair technician diagnose and repair the problem Attempting service or repair without the proper training tools and equipment may cause injury to you and or others It can also damage the generator or lead to hazardous conditions ...

Page 25: ...is tance when pulling recoil starter 1 The engine does not have enough oil add oil 2 Air filter element obstructed by debris Clean according to user manual instruc tions on page 18 Difficulty starting Engine re quires many attempts to start 1 Disconnect load before starting 2 Incorrect oil being used Please refer to the oil usage chart on page 27 in your user s manual 3 Fouled spark plug replace w...

Page 26: ...requirements Wattage consumption Do not exceed the generators maximum peak output Device will not start up 1 Remove all loads reset breaker and check device for defects Do not exceed genera tor rating 2 Ensure device s wattage consumption does not exceed the generator s maximum peak output Engine idle unusually high or low Carburetor in need of tuning For details on how to adjust correctly please ...

Page 27: ...tructed by debris Clean according to user manual instruc tions on page 18 4 Adjust choke lever according to user manual instructions on page 12 5 Incorrect oil being used or insufficient oil level Always ensure high oil levels and use oil according to oil usage chart in user manual on page 27 6 Fouled spark plug replace with equal or greater quality plug Refer to page 27 in your user s manual for ...

Page 28: ...HP 5500RPM 4 Stroke 150CC Hyun dai Motor START Manual Recoil Manual Recoil and Electric Start OUTLETS Two 120V 21 6A AC One 12V 8 3A DC Two 120V 21 6A AC One 12V 8 3A DC One USB FUEL CAPACITY 4 5 L 4 5 L MAX AC OUTPUT 2200W 2800W FUEL TYPE Unleaded Gasoline Minimum Octane of 91 Unleaded Gasoline Minimum Octane of 91 RUNNING TIME 4 2 hours 75 3 7 hours 75 NOISE LEVEL 64dB 7m 65dB 7m FRAME 33 mm Pol...

Page 29: ...IL USAGE OIL GRADE TEMPERATURE SEASON 5W40 0 below Winter 10W40 20 to 5 Spring Fall 15W40 20 Summer 10W30 25 to 15 All season SPARK PLUG COMPATIBILITY BRAND HY2000SI HY2800SEI NGK CR7HS CR7HS DENSO U20FPR U20FPR CHAMPION RZ10YC RZ10YC BOSCH U24BC U24BC ...

Page 30: ...of purchase and does not restart at anytime under any circumstanc es This limited warranty is valid for residential or recreational applications only and only when the generator receives all necessary preventative maintenance as described in the Hyundai Generators Operation Manual The repair or replace ment of a generator will take place within a reasonable period of time during normal business ho...

Page 31: ...MITED WARRANTY 1 Normal engine alternator wear 2 Damage caused by lack of maintenance as described in the Hyundai manuals or negligence by using improper or impure motor oil coolant or fuel 3 Damage caused by accidents improper installation or storage 4 Damage caused by water ingestion submersion or external water damage 5 Damage or non performance caused by operation of the generator set in a mar...

Page 32: ...rvice must be performed by one of our authorized service dealers If you feel your generator is malfunctioning due to a defect or misuse simply contact our customer support center for technical advice a warranty claim or general information Do not return your generator to the place of purchase for repair MIDLAND INTERNATIONAL INC SHOULD BE CONTACTED TO PROVIDE A CASE NUMBER BEFORE WARRANTY WORK CAN...

Page 33: ... to overload or short circuit by stopping the flow of electricity between the generator and device DC SOCKET The receptacle used for charging a 12 V battery DIPSTICK It seals off engine oil fill hole and is used for indicating the engine oil level DRAIN PLUG A plug that can be removed to allow the fluid contents of the engine to be drained off ECON SWITCH This system can be described as a load dep...

Page 34: ...acles OVERLOAD INDICATOR LIGHT If the generator is overloaded or if there is a short circuit in a connected device the overload indicator light red will go ON It will stay ON and after about four seconds the device will shut off and the output indicator light green will go OFF RECOIL STARTER A pull cord is attached to the engine and you pull the T handle attached to the starter cord assembly to sp...

Page 35: ... ensure continued warranty and service support Warranty support cannot be provided without registration from original date of purchase and after transfer of ownership This transfer form must be completed on or before the date that ownership change takes effect Warranty coverage continues from original date of purchase and is not extended by transfer of ownership ...

Page 36: ...36 HY2000si and HY2800sei User Manual ...

Page 37: ... UPC barcode from your product packaging The store date of purchase and product purchase should be clearly visible on the receipt copy YOU MAY ALSO REGISTER ONLINE BY VISITING OUR WEBSITE WWW HYUNDAIPOWER CA If you wish you can confirm your registration by calling customer service at or by email at support hyundaipower ca Please allow one week for mail delivery and processing Please mail all items...

Reviews: