RF Data Modem HWC-M100 / HWC-W100 / HWC-W120
16
∎
Frequency Table according to setting of NET-ID is as following:
NET ID
Frequency
NET ID
Frequency
0
2,405 MHz
8
2,445 MHz
1
2,410 MHz
9
2,450 MHz
2
2,415 MHz
10
2,455 MHz
3
2,420 MHz
11
2,460 MHz
4
2,425 MHz
12
2,465 MHz
5
2,430 MHz
13
2,470 MHz
6
2,435 MHz
14
2,475 MHz
7
2,440 MHz
15
2,480 MHz
< Frequency Table for Network-ID >
∎
All device in a nework has the same NET-ID with the same frequency. It is good to
avoid the use of adjacent NET-ID in a adjacent area to enhance the stability of the
frequency
∎
The stability of a communication can be enhanced that it possibly excludes the
wireless LAN or Bluetooth, and the installation of the Zigbee equipment from the Network
neighboring in which it is installed by using the frequency of the ISM BAND.
∎
Basically, one RF-Master need to be installed in a network and can manage 1~20 APs
and 1~100 EPs at the same time. Number of AP that is installed, is related to the
coverage of each network and Number of EP is same as the number of End-Device that you
want to use in each network.
∎
You can use UP-Link connector to connect with RF-Master. And you can use DN-Link
connector to connect with next AP in which you can use UP-Link.
∎
You can use RS-422 port to connect with End-Device. Assignment of pin is different
according to the type of interface as following:
Pin Number
Description
RS232
RS422
RS485
1
TXD+
TRXD+
2
TXD-
TRXD-
3
RXD+
4
GND
GND
GND
5
GND
GND
GND
6
RXD-
7
TXD
8
RXD
Summary of Contents for HWC-M100
Page 1: ...RF Data Modem HWC M100 HWC W100 HWC W120 User Manual...
Page 6: ...RF Data Modem HWC M100 HWC W100 HWC W120 4 1 3 Product Description RF Master HWC M100...
Page 8: ...RF Data Modem HWC M100 HWC W100 HWC W120 6 RF Modem HWC W100...
Page 10: ...RF Data Modem HWC M100 HWC W100 HWC W120 8 RF Modem HWC W120...