background image

RF Data Modem

HWC-M100
HWC-W100
HWC-W120

User Manual

                                             

Summary of Contents for HWC-M100

Page 1: ...RF Data Modem HWC M100 HWC W100 HWC W120 User Manual...

Page 2: ...od 21 3 2 Communication data 21 4 Communication with the End Device 4 1 Communication Method 22 4 2 Communication Data 22 5 Quick Start for GUI 5 1 Initial Screen after Execution 23 5 2 Network Config...

Page 3: ...8 N 1 Interface with HWC W100 through ethernet Interface with HWC W120 through RF RF Modem HWC W120 RS 232 422 485 for Device 4800 38400bps 8 N 1 Serial port for Debug RS 232 57600bps 8 N 1 Interface...

Page 4: ...on of RSSI according to movement of EP Serial communication type can be selected in RS 232 RS 422 and RS 485 through GUI HWC W100 and HWC W120 Supply Voltage DC 24V Input Range DC 8V DC 32V HWC M100 H...

Page 5: ...RF Data Modem HWC M100 HWC W100 HWC W120 3 1 2 Accessories RF Master HWC M100 RF Modem HWC W100 RF Master HWC W120...

Page 6: ...RF Data Modem HWC M100 HWC W100 HWC W120 4 1 3 Product Description RF Master HWC M100...

Page 7: ...LED Blink in normal operation of device UP LED Ethernet communication with the HOST LOCAL LED Ethernet communication with the AP ALM LED Turn on RED in case of fault operation Power S W DC power on o...

Page 8: ...RF Data Modem HWC M100 HWC W100 HWC W120 6 RF Modem HWC W100...

Page 9: ...l operation of device TX LED turn on in data transmission to End Device RX LED turn on in data reception from End Device ALM LED turn on RED in fault operation Main Div Antenna bi directional antenna...

Page 10: ...RF Data Modem HWC M100 HWC W100 HWC W120 8 RF Modem HWC W120...

Page 11: ...in normal operation of device UP LED Ethernet communication with the HOST LOCAL LED Ethernet communication with the AP ALM LED Turn on RED in case of fault operation Power S W DC power on off switch P...

Page 12: ...RF Data Modem HWC M100 HWC W100 HWC W120 10 2 Installation the device 2 1 Network configuration...

Page 13: ...AP in ethernet communication It can be implemented in multi drop bus for interconnecting RF Master and APs RF Master manages network that relays the communication of HOST and lower equipment AP Access...

Page 14: ...s to link the upper Host another is to link the lower APs UP LINK RF Master could be connected using LAN cable with upper device HOST through RJ 45 connector UP LINK in rear panel of device LOCAL LINK...

Page 15: ...net Mask 255 255 255 0 Gateway 192 168 10 254 MAC Address 00 0A 1F 00 EC 01 Network Parameter Window in GUI Start up procedure of RF Master Supply power 8 32VDC Connect ethernet cable to UP LINK Port...

Page 16: ...Device by wireless And It can be used as AP to communicate with Host or EP to communicate with End Device by selection of dip switch in front panel of it In AP mode you need to set Net ID Device ID AP...

Page 17: ...RITY BIT Selection of use of parity bit even or none INTERFACE Type of Interface between EP and End Device RS232 RS485 RS422 AP EP Mode You must turn the dip switch for AP EP mode to OFF NET ID 0 15 S...

Page 18: ...reless LAN or Bluetooth and the installation of the Zigbee equipment from the Network neighboring in which it is installed by using the frequency of the ISM BAND Basically one RF Master need to be ins...

Page 19: ...ip switch for AP EP mode to ON In AP Mode RF Modem communicate with RF Master through Ethernet Its network parameter IP address subnet mask gateway MAC address is automatically configured by Device ID...

Page 20: ...RF Data Modem HWC M100 HWC W100 HWC W120 18 AP Information Window in GUI EP Information Window in GUI...

Page 21: ...2 410 MHz 9 2 450 MHz 2 2 415 MHz 10 2 455 MHz 3 2 420 MHz 11 2 460 MHz 4 2 425 MHz 12 2 465 MHz 5 2 430 MHz 13 2 470 MHz 6 2 435 MHz 14 2 475 MHz 7 2 440 MHz 15 2 480 MHz All device in a nework has t...

Page 22: ...the number of End Device that you want to use in each network You can use Serial port to connect with End Device Assignment of pin is differnet according to the type of interface as following pin num...

Page 23: ...thernet Protocol is as follows RAV Layer Header Information Terminator UDP Layer UDP Header UDP Information IP Layer IP Header IP Information MAC Layer MAC Header MAC Information Data of the UDP Infor...

Page 24: ...od is selected by dip switch for mode select It could support one of RS232 RS422 and RS485 and the assignment of pin is different according to selection You can also configure data bit stop bit and pa...

Page 25: ...igure Network or Request Device List There is the following differences between Configure Network and Request Device List Configure Network It send commands to Master to gather the list of AP EP again...

Page 26: ...Data Modem HWC M100 HWC W100 HWC W120 24 you can see AP 0 EP 0 by pressing F5 Key It could be different with real device list and This is the function that you can see device information without Mast...

Page 27: ...e EP that communicate with Master and owner member relation between them Device list of the left window shows result of request briefly You must click Network Configuration to see more detail The foll...

Page 28: ...rmation to communicate with HOST These are network information of the Master AP Link Network information of communicate with AP User do not need to set this information Range of EP Number of EP that i...

Page 29: ...stem Version Firmware version of AP Master Link Network information to communicate with Master User do not need to set this information Config Configuration information of AP Caution 1 When you want t...

Page 30: ...rk information to communicate with Master User do not need to set this information Config Configuration information of EP Comm of End Device Information of serial port to communicate with End device E...

Page 31: ...an set till a maximum 200 second and this time means the X axis For example If the time setting was 10 seconds receiver sensitivity data of 10 second amount is drawn on a screen The time itself to mea...

Page 32: ...retrieved and the RSSI graph can be drawn again The following is for the button and the check box Numeric It sets up whether the numerical value display will be indicated or not Delete It deletes all...

Page 33: ...a value between 1 10 second 2 Set the option Color value If the value is more than the set value the value is expressed as the red letter In other case It is expressed as the black letter That is user...

Page 34: ...function in which we know whether the communication state with each EP is good or not The following is the usage Request Status of Communication It require the number of transmission and reception It...

Page 35: ...w up the dialog box Click the OK button after selecting the download file The file extension is MAU Master AP RFU and EP RFU If the file extension is different please confirm the device selected in le...

Page 36: ...you can change the configuration of communication 4 At first confirm whether the PC is connected with the device through the serial cable or LAN cable And select one of Serial UDP 5 In case of serial...

Page 37: ...please confirm the communication configuration again The error is in following case In serial mode when the comport is set up incorrectly In UDP mode when the TargetIP is set to 0 0 0 0 or the Target...

Page 38: ...RF Data Modem HWC M100 HWC W100 HWC W120 36 6 Dimension 6 1 RF Master HWC M100 TOP VIEW FRONT VIEW REAR VIEW...

Page 39: ...RF Data Modem HWC M100 HWC W100 HWC W120 37 6 2 RF Modem HWC W100 TOP VIEW FRONT VIEW REAR VIEW...

Page 40: ...RF Data Modem HWC M100 HWC W100 HWC W120 38 6 3 RF Modem HWC W120 TOP VIEW FRONT VIEW REAR VIEW...

Page 41: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the...

Page 42: ...ibed below are NOT to be covered by warranty Users faults by lack of care Unauthorised electric currency connection defaults Faults by the users own intention of dismantle or repairs Demages caused by...

Reviews: