4. OPERATING THE GENERATOR
•
Do not loosen or readjust either the engine speed limiting bolt or the
fuel injection limiting bolt as this will cause the performance of the
generator to be affected.
4.1.
Starting.
4.1.1.
Turn the main AC switch to the 'OFF' position.
4.1.2.
Make sure that the machine has fuel for the task.
4.1.3.
Make sure the emergency STOP switch is out
(turn anti-clockwise).
4.1.4.
Set the engine speed lever is set to ‘RUN’.
4.1.5.
Turn the starting key clockwise to the 'START'
position.
4.1.6.
Remove your hand from the key as soon as the
engine starts.
4.1.7.
If the engine does not start after 10 seconds, wait
15 seconds before trying again. Excessive start attempts will cause the battery to
flatten.
4.1.8.
If it does not start after 3 attempts, or runs intermittently with excessive smoke
check that the fuel system is fully primed.
4.1.8.1.
Priming - before starting to prime make sure that there is fuel in tank and
that you can contain any fuel spilt.
4.1.8.1.1.
It is done by releasing the pipe clip on the diesel fuel line connected to
the injector pump. Make sure you pinch the fuel line and then release slowly
until all air is released and fuel appears.
4.1.8.1.2.
When fuel appears replace pipe onto the injector pump and replace
clip. Clear up any fuel spills before restarting.
4.1.8.1.3.
The above may be necessary when new, or if the machine runs out of
fuel.
Page 16
Rev 3
Summary of Contents for DHY6000LR
Page 2: ...Page 2 Rev 3 ...
Page 11: ...2 MACHINELAYOUT Page 11 Rev 3 ...
Page 23: ...11 WIRINGDIAGRAM 11 1 N B Subject to change without prior notice Page 23 Rev 3 ...
Page 25: ...12 SERVICE RECORD SHEET Date Hours Maintenanceundertaken Name Page 25 Rev 3 ...
Page 29: ...NOTES Page 29 Rev 3 ...
Page 30: ...NOTES Page 30 Rev 3 ...
Page 31: ...NOTES Page 31 Rev 3 ...