3501 Actuator
INSTALLATION REFERENCE MANUAL
20
www.hysecurity.com • 800-321-9947
MX4754 Rev. B ©2019
For
dual
opening gates, wire the actuator cable to the control board as shown below:
At this point it is necessary to apply power to the control board in order to set the limit collars in the next
instruction. Refer to the control box installation manual for instructions on installing the control box and
applying power to the control board and the actuator motor.
NOTE:
Apply power to the control board, but do not put the control board through the “Learning”
process described in the Control Box installation manual until after the limit collars have been adjusted
per INSTRUCTION 14 in this manual.
IMAGE 12C-1:
DUAL OPENING GATE: ACTUATOR TO CONTROL BOARD WIRING
NOTE:
If a gate moves in
opposite direction
from what is expected,
reverse the motor power
lead wiring (red & black
wires) for that motor.
MOTOR 1
MOTOR 2
WHITE
ORANGE
GREEN
ORANGE
GREEN
WHITE
DO NOT USE
BLACK
RED
RED
BLACK
3501 ACTUATOR
LEFT HINGE
3501 ACTUATOR
RIGHT HINGE
3501 ACTUATOR
MOTOR LEADS
3501 ACTUATOR
MOTOR LEADS
DUAL OPENING GATE
DUAL OPENING GATE
WIRE ACTUATOR CABLE TO CONTROL BOARD (DUAL)
INSTALL CONTROL BOX AND APPLY POWER
12C
13
IMPORTANT!
There is a “motor switch” on the bottom of the drive chassis used to de-energize the motor for manually
opening the gate. However, if this switch is inadvertantly turned OFF during installation, the motor will
not operate. See INSTRUCTION 16, IMAGE 16-1 for switch location and ON/OFF orientation in case this
is an issue.