INTERFACE CABLE REPLACEMENT

Field Service Bulletin 

5

3

4

12

13

14

6

5

Powermax45

Powermax65/85 

Powermax65/85/105 SYNC

2

1

Refer to the following table when connecting the Powermax system to a torch height controller or CNC controller with a 

machine interface cable.

Signal

Type

Notes

Connector 

sockets

Cable wires

Start (start 

plasma)

Input

Normally open. 

18 VDC open circuit voltage at START terminals. 

Requires dry contact closure to activate.

3, 4

Green, black

Transfer 

(start 

machine 

motion)

Output

Normally open. Dry contact closure when the arc 

transfers. 

120 VAC/1 A maximum at the machine interface relay 

or switching device (supplied by the customer).

12, 14

Red, black

Ground

Ground

13

Voltage 

divider

Output

Powermax45: Divided arc signal of 50:1 (provides a 

maximum of 7 V)

5 (-), 

 

6 (+)

Black (-), white (+)

Powermax65/85, Powermax65/85/105 SYNC: 

Divided arc signal of 20:1, 21.1:1, 30:1, 40:1, 50:1 

(provides a maximum of 18 V).
Arc voltage sockets 5 and 6 are used for pin-to-pin 

connection to legacy cables.
Sockets 1 and 2 are duplicate arc voltage sockets 

for future use. Sockets 1 and 2 are not used for most 

installations.

5, 1 (-) 

(Electrode)
6, 2 (+) 

(Work)

Black (-), white (+)

Summary of Contents for Powermax45 XP

Page 1: ...wermax65 85 105 125 Powermax65 85 105 SYNC Machine Interface Cable Kit Remplacement du c ble d interface Field Service Bulletin Bulletin de service sur le terrain 806180 Revision 7 December 2021 R vis...

Page 2: ......

Page 3: ...vice Bulletin Powermax45 XP 105 125 systems Complete instructions for installing this kit are included in the Service Manual To download the Service Manual go to www hypertherm com docs Powermax105 Se...

Page 4: ...ols The built in voltage divider provides a scaled down arc voltage of 20 1 21 1 1 30 1 40 1 and 50 1 maximum output of 18 V An optional receptacle on the rear of the power supply provides access to t...

Page 5: ...69C for more safety information NOTICE Static electricity can cause damage to printed circuit boards PCBs Use correct precautions when you touch PCBs Keep PCBs in antistatic containers Put on a ground...

Page 6: ...e interface cable must be performed by a qualified service technician To install a machine interface cable 1 Turn OFF the power and disconnect the power cord 2 Remove the machine interface receptacle...

Page 7: ...r start machine motion Output Normally open Dry contact closure when the arc transfers 120 VAC 1 A maximum at the machine interface relay or switching device supplied by the customer 12 14 Red black G...

Page 8: ...INTERFACE CABLE REPLACEMENT 6 Field Service Bulletin...

Page 9: ...yst mes Powermax45 XP 105 125 Les instructions compl tes pour l installation de ce kit sont incluses dans le Manuel de service Pour t l charger le Manuel de service aller l adresse www hypertherm com...

Page 10: ...nt gr offre une tension d arc r duite de 20 1 21 1 1 30 1 40 1 et 50 1 sortie maximale de 18 V Une prise facultative situ e l arri re de la source de courant permet d acc der la tension d arc r duite...

Page 11: ...conformit et de s curit 80669C pour obtenir des consignes de s curit suppl mentaires AVIS L lectricit statique peut endommager les cartes circuits imprim s Prendre des pr cautions ad quates lors de la...

Page 12: ...par un technicien de service qualifi Pour installer un c ble d interface de machine 1 Couper l alimentation OFF et d brancher le cordon d alimentation 2 D poser le couvercle de la prise de l interfac...

Page 13: ...ine Sortie Normalement ouvert Fermeture contact sec lors du transfert de l arc 120 V c a 1 A maximum au relais d interface de la machine ou l interrupteur fourni par le client 12 14 Rouge noir Terre T...

Page 14: ...REMPLACEMENT DU C BLE D INTERFACE a 6 Bulletin de service sur le terrain...

Page 15: ......

Page 16: ...Nederland 31 165 596907 Tel Hypertherm Shanghai Trading Co Ltd PR China 200231 86 21 80231122 Tel Hypertherm S Pte Ltd Singapore 349248 65 6841 2489 Tel Hypertherm Plasmatechnik GmbH 63452 Hanau Germ...

Reviews: