58
EDGE Pro Ti CNC
Instruction Manual 807660
Installation
Emergency stop (E-stop) connection
Sample E-stop circuit
Figure 20 illustrates an example of an E-stop that a table manufacturer might implement. The CPC for this circuit
connects to the E-stop connector on the rear enclosure of the CNC and to the built-in safety circuit within the EDGE Pro
Ti CNC, shown in Figure 21.
The E-stop in Figure 20 uses Hypertherm components; an E-stop switch (428025), safety relay (003239), and reset
switch (428026) and uses the EDGE Pro Ti E-stop cable to connect to the safety circuit within the CNC. Other
components require a different design.
Figure 20 Example of an E-stop circuit
E-Stop enclosure
(Supplied by the table manufacturer)
Safety
relay
Reset switch
AC fused disconnect
AC
Disconnect
Connect tab to ground screw on the rear
panel of the CNC
Brown
Jumper
Green
Blue
Red
Violet
Black
Orange
White
E-stop switch
Normally closed
Normally open
Reset S34
24
23
13
14
A2
41
3
4
A1
S12
S52
S21
S22
S11
Jumper
42
E-stop cable
Connects to the E-stop CPC
Lamp
X1
X2
2
2
1
1
1
2
3
7
6
5
4
10
9
8
12
11
15
14
13
Yellow
Grey
CPC
Cable shield
Summary of Contents for EDGE Pro Ti
Page 1: ...Instruction Manual 807660 Revision 3 EDGE Pro Ti Shape Cutting Control...
Page 18: ...xviii Safety and compliance Safety...
Page 48: ...48 EDGE Pro Ti CNC Instruction Manual 807660 Installation Mounting the THC...
Page 92: ...92 EDGE Pro Ti CNC Instruction Manual 807660 Installation Hypernet and LAN cable...
Page 154: ...154 EDGE Pro Ti CNC Instruction Manual 807660 Wiring Diagrams Wiring diagram symbols...