EDGE Pro Ti CNC
Instruction Manual 807660
47
Installation
Mounting the THC
Example grounding diagram
Note:
This example is based on practices in North America. Other regions can have different local or national
electrical codes. Hypertherm recommends that you consult your local and national electrical codes to make sure
that the grounding and shielding practices that you use satisfy the requirements for your location.
Chassis and RFI ground
AC earth ground (PE)
1
2
3
4
5
6
7
8
9
10
11
12
13
1
Cutting table
2
Gantry
3
Plasma system
4
Table ground bus bar
5
Gantry ground bus bar
6
Torch height control lifter (ArcGlide, Sensor THC,
Sensor PHC, or other)
7
RHF console (not on all systems). Connect to
table ground bus bar.
8, 9
System-specific component such as metering
console, gas console, or selection console
10
CNC chassis
11
Torch height control module
(ArcGlide, Command THC)
12
System-specific component such as a cooler or
chiller
13
DC power ground