Duramax Hyamp Torches with 46 m (150 foot) Leads
4
810260
Field Service Bulletin
Powermax125
For information on Powermax125 specifications, system operation, and
part numbers, refer to the
Powermax125 Operator Manual
(808080).
For information on Duramax Hyamp long handheld torches, refer to the
Duramax Hyamp Long Handheld Torches Service Manual
(808290).
What to expect with a 46-m (150-foot) torch lead
Hypertherm recommends using a 46-m (150-foot) work lead with a 46-m
(150-foot) torch to ensure that you do not cut too far from where you
attach the work clamp.
059668
Duramax Hyamp 90° long handheld torch assembly with 1.2 m (4 foot) extension and
46 m (150 foot) lead
428762
Kit: Duramax Hyamp hand torch lead replacement, 46 m (150 feet)
428761
Kit: Duramax Hyamp 180° machine torch lead replacement, 46 m (150 feet)
223744
125 A work lead with ring terminal, 46 m (150 feet)
223737
125 A work lead with hand clamp, 46 m (150 feet)
428755
Remote start pendant for machine torch, 46 m (150 feet)
Part number
Description
CAUTION
Always connect the work clamp to the workpiece you are cutting or to the cutting table.
Do not cut far away from where you attached the work clamp. This can result in damage to
equipment or injury to anyone who interrupts the electrical circuit.
NOTICE
Be careful with the routing of torch leads.
Do not place the torch lead where people will step on it or drive over it. This can cause
permanent damage to the lead.
Prevent the lead from routing along sharp edges or angles that can damage it.
Make sure the lead is not kinked or twisted. This can cause decreased cut performance.
Do not wind excess lead length into a coil. This can cause decreased cut performance. Instead,
put the excess lead down flat or into a figure-8 shape.