background image

Hypertherm Inc.

Etna Road, P.O. Box 5010
Hanover, NH 03755 USA
603-643-3441 Tel (Main Office)
603-643-5352 Fax (All Departments)
[email protected] (Main Office Email)

800-643-9878 Tel (Technical Service)

[email protected] (Technical Service Email)

800-737-2978 Tel (Customer Service)

[email protected] (Customer Service Email)

866-643-7711 Tel (Return Materials Authorization)
877-371-2876 Fax (Return Materials Authorization)

[email protected] (RMA email)

Hypertherm México, S.A. de C.V.

Avenida Toluca No. 444, Anexo 1,
Colonia Olivar de los Padres
Delegación Álvaro Obregón
México, D.F. C.P. 01780
52 55 5681 8109 Tel
52 55 5683 2127 Fax
[email protected] (Technical Service Email)

Hypertherm Plasmatechnik GmbH

Sophie-Scholl-Platz 5
63452 Hanau 
Germany
00 800 33 24 97 37 Tel
00 800 49 73 73 29 Fax

31 (0) 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)

[email protected] (Technical Service Email)

Hypertherm (Singapore) Pte Ltd.

82 Genting Lane
Media Centre
Annexe Block #A01-01
Singapore 349567, Republic of Singapore
65 6841 2489 Tel
65 6841 2490 Fax 
[email protected] (Marketing Email)
[email protected] (Technical Service Email)

Hypertherm Japan Ltd.

Level 9, Edobori Center Building
2-1-1 Edobori, Nishi-ku
Osaka 550-0002 Japan
81 6 6225 1183 Tel
81 6 6225 1184 Fax
[email protected] (Main Office Email)
[email protected] (Technical Service Email)

Hypertherm Europe B.V.

Vaartveld 9, 4704 SE 
Roosendaal, Nederland
31 165 596907 Tel
31 165 596901 Fax
31 165 596908 Tel (Marketing)

31 (0) 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)

[email protected]  
(Technical Service Email)

Hypertherm (Shanghai) Trading Co., Ltd.

B301, 495 ShangZhong Road
Shanghai, 200231
PR China
86-21-80231122 Tel
86-21-80231120 Fax

86-21-80231128 Tel (Technical Service)

[email protected]  
(Technical Service Email)

South America & Central America: Hypertherm Brasil Ltda.

Rua Bras Cubas, 231 – Jardim Maia
Guarulhos, SP – Brasil
CEP 07115-030
55 11 2409 2636 Tel
[email protected] (Technical Service Email)

Hypertherm Korea Branch

#3904. APEC-ro 17. Heaundae-gu. Busan.
Korea 48060
82 (0)51 747 0358 Tel
82 (0)51 701 0358 Fax
[email protected] (Marketing Email)
[email protected]  
(Technical Service Email)

Hypertherm Pty Limited

GPO Box 4836 
Sydney NSW 2001, Australia
61 (0) 437 606 995 Tel
61 7 3219 9010 Fax
[email protected] (Main Office Email)
[email protected]  
(Technical Service Email)

Hypertherm (India) Thermal Cutting Pvt. Ltd

A-18 / B-1 Extension,
Mohan Co-Operative Industrial Estate,
Mathura Road, New Delhi 110044, India
91-11-40521201/ 2/ 3 Tel
91-11 40521204 Fax
[email protected] (Main Office Email)
[email protected]  
(Technical Service Email)

1/28/16

© 2018 Hypertherm Inc. All rights reserved. Tous droits réservés.

Duramax and Hypertherm are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. All other trademarks are the property of their 
respective holders.

Environmental stewardship is one of Hypertherm’s core values, and it is critical to our success and our customers’ success. We are striving to reduce the environmental 
impact of everything we do. For more information: www.hypertherm.com/environment.

Duramax et Hypertherm sont des marques d’Hypertherm Inc. qui peuvent être déposées aux États-Unis ou dans d’autres pays. Toutes les autres marques de commerce sont 
la propriété de leurs détenteurs respectifs.

Une bonne gestion environnementale est l’une des valeurs fondamentales d’Hypertherm et est essentielle à notre réussite et à celle de nos clients. Nous travaillons sans 
relâche pour réduire l’incidence sur l’environnement de toutes nos activités. Pour en savoir plus : www.hypertherm.com/environment.

Summary of Contents for 059664

Page 1: ...p Torches with 46 m 150 foot Leads Powermax125 Torches Duramax Hyamp avec faisceaux de 46 m Powermax125 Field Service Bulletin Bulletin de service sur le terrain 810260 Revision 0 Révision 0 July 2018 Juillet 2018 ...

Page 2: ...1 80231122 Tel 86 21 80231120 Fax 86 21 80231128 Tel Technical Service techsupport china hypertherm com Technical Service Email South America Central America Hypertherm Brasil Ltda Rua Bras Cubas 231 Jardim Maia Guarulhos SP Brasil CEP 07115 030 55 11 2409 2636 Tel tecnico sa hypertherm com Technical Service Email Hypertherm Korea Branch 3904 APEC ro 17 Heaundae gu Busan Korea 48060 82 0 51 747 03...

Page 3: ...fer to the Powermax125 Service Manual 808070 Download the manual at www hypertherm com docs Duramax Hyamp torches with 46 m 150 foot torch leads cannot be used with any other Powermax systems Part numbers WARNING ELECTRIC SHOCK CAN KILL Disconnect all electric power before doing any installation or maintenance All work requiring removal of the plasma power supply cover must be done by a qualified ...

Page 4: ...torch lead replacement 46 m 150 feet 223744 125 A work lead with ring terminal 46 m 150 feet 223737 125 A work lead with hand clamp 46 m 150 feet 428755 Remote start pendant for machine torch 46 m 150 feet Part number Description CAUTION Always connect the work clamp to the workpiece you are cutting or to the cutting table Do not cut far away from where you attached the work clamp This can result ...

Page 5: ...1 2 inch Use a gas inlet hose of the shortest possible length Torch fire rate A 46 m 150 foot torch lead causes the torch to fire a plasma arc at a slightly slower rate 46 m 150 foot torches take up to 1 second longer to fire than torches with shorter lead lengths Component weights Torch lead length Minimum inlet pressure cutting Minimum inlet pressure gouging 7 6 m 25 feet 5 9 bar 85 psi 4 1 bar ...

Page 6: ...u connect a 46 m 150 foot torch to the plasma power supply the lead length displays as 100 on the service screen For example the T125H100 torch identifier is made up of 3 parts as follows 125 amperage H hand torch M machine torch 100 lead length in feet in this case 100 indicates the torch lead is 100 or more feet ...

Page 7: ...seur de signal numérique reportez vous au Powermax125 manuel de service 808070 Télécharger le manuel depuis le www hypertherm com docs Les torches Duramax Hyamp avec faisceau de 46 m ne peuvent pas être utilisées avec d autres systèmes Powermax Numéros de référence AVERTISSEMENT UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL Débrancher toute alimentation électrique avant d effectuer toute installation ou tou...

Page 8: ...max Hyamp 180 de rechange de 46 m 223744 Câble de retour 125 A avec cosse ronde 46 m 223737 Câble de retour 125 A avec serre joint 46 m 428755 Suspension télécommandée pour torche machine 46 m Numéro de référence Description ATTENTION Toujours connecter le connecteur de pièce à la pièce à couper lors du coupage ou à la table de coupe Ne pas couper loin du point de fixation du connecteur de pièce C...

Page 9: ... un tuyau d entrée de gaz avec un diamètre interne minimum de 12 mm Utilisez un tuyau d entrée de gaz le plus court possible Vitesse d amorçage de la torche Un faisceau de torche de 46 m fait que la torche amorce un arc plasma à une vitesse légèrement inférieure Les torches de 46 m prennent jusqu à une seconde de plus pour l amorçage que les modèles avec des faisceaux plus courts Poids des composa...

Page 10: ...orche de 46 m à la source de courant plasma la longueur du faisceau s affiche comme 100 sur l écran de service Par exemple l identifiant de la torche T125H100 est composé de trois parties comme suit 125 intensité H torche manuelle M torche machine 100 longueur du faisceau en pied dans ce cas 100 indique que le faisceau de torche est de 100 pieds ou plus ...

Reviews: