Seite 13
Best.-Nr. / Item-No. / art. 028-1040
IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS FOR
LITHIUM-POLYMER-BATTERIES
1. General Guidelines and Warnings
• LiPo batteries are NOT charged as you receive them. They contain approximately 50% of a full charge as recommended for
shipment and long term storage .
• Use Lithium Polymer specific chargers only. Do not use a NiCd or NiMh charger - Failure to do so may cause a fire, which may
result in personal injury and property damage.
• Never charge batteries unattended. When charging LiPo batteries you should always remain in constant observation to monitor
the charging process and react to potential problems that may occur.
• Some LiPo chargers on the market may have technical deficiencies that may cause them to charge LiPo batteries incorrectly. It is
solely the responsibility of the user to assure that the charger used works properly.
• If at any time you witness a battery starting to balloon or swell up, discontinue the charging process immediately. Disconnect the
battery and place it in a safe observation area for approximately 15 minutes. Continuing to charge a battery that has begun
to swell will result in fire.
• Battery observation should occur in a safe area outside of any building or vehicle and away from any combustible material.
The middle of a cement driveway is a good example of a safe observation area.
• Shorts can cause fires! If you accidentally short the wires, the battery must be placed in a safe area for observation for
approximately 15 minutes. Additionally, be mindful of the burn danger that may occur due to a short across jewelry (such as
rings on your fingers).
• Chemical reactions are not instantaneous, a battery that has been shorted may not ignite for 10 minutes.
• All crash batteries, even if not deformed, should be placed in a safe area for observation for at least 15 minutes.
• If for any reason you need to cut the terminal wires, cut each wire separately, ensuring the wires do not become shorted
across the cutting tool.
2. Charging Process
• Make a visual inspection of the pack. Checking for any damaged leads, connectors, broken/cracked shrink covering, puffiness
or other irregularities.
• Before installing or changing the connector, check the voltage of the pack using a digital voltmeter. All new packs ship at
approximately 3.80V to 3.9V per cell. For example: A 2S pack should read approximately 7.60V to 7.8V, A 3S pack should read
approximately 11.40V to 11.7V etc
• If any damage to the pack or leads is found, or the voltage is significantly less for your pack than specified above, do not
attempt to charge or fly the pack; contact AG Power directly as soon as possible.
• Never charge batteries unattended.
• Charge in an isolated area, away from flammable materials.
• Let the battery cool down to ambient temperature before charging.
• Do not charge battery packs in series. Charge each battery pack individually. Overcharging of one or the other battery may
occur resulting in fire
• When selecting the cell count or voltage for charging purposes, select the cell count and voltage as it appears on the battery
label. Selecting a cell count or voltage other than the one printed on the label may result in overcharging and fire. As a safety
precaution, please confirm that the information printed on the battery is correct. For example: If a battery label indicates that it is
a 3 cell battery (3S), it's voltage should read between 11.4 and 11.7 volts. This battery must be charged as a 3 cell battery
(peak of 12.6V).
• You must check the pack voltage after each flight before re-charging. Do not attempt to charge any pack if the unloaded
individual cell voltages are less than 3.3V. For example: Do not charge a 2-cell pack if below 6.6V Do not charge a 3 cell pack
if below 9.9V
• NORMAL CHARGING: The charge rate should not exceed 1C (one times the capacity of the battery, unless otherwise noted*).
Higher setting may cause problems which can result in fire. For example: Charge a 730 mAh battery at or below 0.73Amps.
Charge a 5000 mAh battery at or below 5Amps.
3. Storage & Transportation
• Store batteries at room temperature
• If storing longer than a couple of weeks; batteries should be stored at 3.8V/cell to 3.9V/cell (approximately 50% charged).
• Do not expose battery packs to direct sunlight (heat) for extended periods.
• When transporting or temporarily storing in a vehicle, temperature range s should be greater than 5c but no more than 35c
• Storing Lipo batteries at temperatures greater than 40c for extended periods of time (more than 2 hours) may cause damage
to battery and possible fire.
4. Caring for Battery
• Only charge a LiPo battery with a good quality Lithium Polymer charger. A poor quality charger can be dangerous!
• Set voltage and current correctly (failure to do so can cause fire).
• Please check pack voltage after the first charge. For example; a 2 Cell battery should measure 8.4V (8.30 to 8.44), a 3 cell
battery should measure 12.6V (12.45 to 12.66).
• Do not discharge a battery to a level below 3V per cell under load. Discharging below 3V per cell can deteriorate battery
performance. Be sure to set your ESC for the proper cut off voltage (6.0V cut off for 2S packs, 9.0V cut off for 3S packs, etc).
• Use caution to avoid puncture of the battery. Puncturing a LiPo battery may cause a fire.
• Always allow a battery to cool down to ambient temperature before re-charging.
Batteries that lose 20% of their capacity must be removed from service and disposed of properly. Discharge the battery to 3V/Cell,
making sure output wires are insulated, then wrap battery in a bag for disposal.
Summary of Contents for JODEL ROBIN DR-400