GMS81508/16
47
2.14. RESET FUNCTION
To reset the device, maintain the RESET="L" at least 8 machine cycle after power supplying and
oscillation stabilization.
RESET terminal is organized as schmitt input.
If initial value is undefined, it is needed initialize by a S/W.
RESET Operation Timing
Opcode
System Clock
Instruction Fetch
?
Start
FFFF
FFFE
?
?
?
Address Bus
FE
?
ADH
ADL
?
FFFE
H
, is vector address and ADL, ADH is start address of main program
as vector contents
RESET Process Step
Main Program
?
?
Data Bus
Internal Read
RESET