SPA

Manual

Spa Remote Touch 

READ AND SAVE THESE INSTRUCTIONS!

ÁSPART.ENoÈ

SPART.EN

Summary of Contents for Spa Touch Control

Page 1: ...SPA Manual Spa Remote Touch READ AND SAVE THESE INSTRUCTIONS SPART ENo SPART EN...

Page 2: ...11 2014 SPART EN All Rights reserved HygroMatik GmbH grants the legal user of this product or device the right to use the Work s solely within the scope of the legitimate operation of the product or...

Page 3: ...9 3 3 Quick Access Functions Overview 10 4 Operating the Spa Remote Touch on User and Operator Levels 11 4 1 Accessing the Main Menu 11 4 2 Overview on Submenus 11 4 3 Access to Operator Level 12 4 4...

Page 4: ...cs Terms used with graphics or drawings 1 2 Documentation Scope of Supply HygroMatic steam ge nerators a re always a ccompanied by two operating manuals one for the unit itself and one for the control...

Page 5: ...atic discharges In order to safeguard these components during installation and servicing steps must be taken to protect against ESD Reminder Materials and c onsumables must be handled and or dis posed...

Page 6: ...ust be p rovided in th e ro om to e nsure closur e of the h umidifier s water supply in the event of a leak Electrical Work on the electrical system must be performed by qualified person nel Disconnec...

Page 7: ...e cradle the Spa Remote Touch can be run for up to thr ee hours on the b atteries inegrated in the remote control The charging cradle is per man antly connected to the steam generator through a commun...

Page 8: ...quently used functions Menu Enable steam production Essence injection Timer function ECO function Light function Symbol Status Description perma nently on preset Timer mode is activated blinking steam...

Page 9: ...ith water white Ready for Use the safety chain clamp 1 2 is open the device is not enabled for steam production dark blue ECO device operates in ECO mode orange No Demand the requirement is below the...

Page 10: ...timer mode Hourly daily or weekly timer functions can be set on operator level Menu function Tapping on the key MENU takes youto the main menu with the submenus Steam bath Timer ECO Device configurat...

Page 11: ...l temperature and switching the essence dosing on and off From guest lev el t he re turn to us er lev el r equires a 5 ch aracter n umeric password that can be set on operator level Note The fu nction...

Page 12: ...ser level as shown by the User indication in white in the appropri ate display field After typing in 010 as an access code the character colour changes to grey Instead of Password entry Operator is di...

Page 13: ...SPA Page 13 4 4 Menu Scheme...

Page 14: ...essence submenu and select On Intensity Select Intensity to set the intensity of the essence The intensity grade selected is shown in a 11 stage diagram Touch the diagram in order to change the intens...

Page 15: ...rating the Error C Max alarm message Select Hysteresis Temp max this parameter determines at which temperature with respect to the temperature set value steam generation is cut and the alarm Error C...

Page 16: ...an for permanent operation Quit the menu with Changing the switch off temperature hysteresis of the fan Select Automatic Select Hysteresis to set the temperature hysteresis set temperature minus hyste...

Page 17: ...timer function Quit the menu with 4 4 2 3 Modes The following timer modes are available Hourly Daily Weekly Setting of the relevant times ca n be made in Settings The program selected is shown in the...

Page 18: ...ng allows for the definiti on of th e stea m p roduction pe riod After timer start the remaining period is displayed in the button field Steam production period Select Steam production period after pr...

Page 19: ...reselection of Weekly program Type in the times for start and stop of steam production Confirm by pressing OK or discard by using the ESC button Quit the menu with 4 4 3 ECO Mode The steam generator s...

Page 20: ...point temperature lower than the standard value Please note Standby Heating and temperature preservation can not be active at the same time Selection of the ECO function intended Select ECO Settings...

Page 21: ...el also provides expanded access to all parameters Only password entry activates the operator level If there has not been an entry for a period of 15 minutes control automatically switches back to use...

Page 22: ...hile the charging cradle is connected to the turned on steam generator In the next step the charging cradle must be prepared To do so the two pins on jumper JP1 on the board of the charging cradle hav...

Page 23: ...correct password is typed in The password set is dis played in the Set password button field The submenu allows for the following actions Activate Set password Activate guest mode Select Activate ente...

Page 24: ...4 7 Name Plate The nameplate holds the following information concerning the steam humidifier connected Serial number Software version of control unit Year of production Deutsch English Fran ais ESpa...

Page 25: ...arameters Select Mode of operation Use arrows to select 1 step or PI controller Confirm by pressing OK or discard the input using the ESC button Quit the menu with 4 4 8 2 Service In this submenu the...

Page 26: ...ng criteria have to be considered for the start of the blow down o peration device type recognition is automatic b y the r emote control Additionally and not depending on the type of humidifier stand...

Page 27: ...blow down is initiated Partial full blow down These parameters define the operating time of the pump in s during blow down with respect to the mode chosen Setting up of partial blow down counter Selec...

Page 28: ...t using ESC but ton Quit the menu with Setting up of full blow down time Select Operator menu Select blow down Select full blow down time Type in a value in the range from 0 255 s for heater humidi fi...

Page 29: ...parameter C16 and so on Standby heating is only operational in ECO mode when A17 on On A17 off tempera ture preservation is operational i e the steam bath temperature is held on a lower set value as d...

Page 30: ...e set value and G1 Hys teresis 1 step controller Example G2 is set to 45 C and G1 is set to 1K t The s team generator will be switched of at 46 C and will be switched on again at 45 C Steam bath tempe...

Page 31: ...oth types of humidifiers Operator menu Blow down Par tial blow down time H7 H17 Full blow down counter 0 9999 ELDB 0 9999 kg HKDB number of filling cycles before full blow down is initiated electrode...

Page 32: ...eplate S4 Unit type Reading automatically read Main menu Nameplate S5 Year of produc tion Reading automatically read Main menu Nameplate S6 Serial number Reading automatically read Main menu Nameplate...

Page 33: ...ctronics is ma de through a st andard RJ45 p atch cable to be pro vided by the customer The photos below show the cabling on the bot tom side of the control unit housing and inside the charging cradle...

Page 34: ...Page 34 The pho tos below sho w the inter nal cab ling of the contro l un it for connecting the Spa Remote Touch charging cradle Internal cabling of control unit Internal cabling of control unit deta...

Page 35: ...O HLFKQXQJ 1U HQHQQXQJ DWHL 63 7RXFK 5HPRWH 6 6 520 7 LVH 0HLWQHU 6WU HQVWHGW 8O EXUJ HUPDQ 7HOHID 3KRQH bQGHUXQJ DWXP 1DPH HDUE HSU 1RUP DWXP XVW D UHLJDEH XH 5W 237 21 9RUEHUHLWXQJ 63 7RXFK 5HPRWH 2...

Page 36: ......