Page 38
HygroMatik provides a water hose (56) with a cap nut at both
ends which can be used for water installation.
Install as follows:
Screw and tighten the cap nut with its inner seal ring around the
water supply screw connection that protrudes from the base.
Excessive tightening will destroy the fitting. The valve strainer
(29) must be placed inside the solenoid valve.
Use the cap nut (internal thread ¾“) with inner seal for connec-
tion to the customer-provided water system.
6.4
Feed from Holding Tank
If a holding tank will be used to supply water, the „option sole-
noid valve 0-10bar” must be ordered. Make sure that the feed
height is at least 0.5 meter. If the height is less than 0.5 m, insert
a feed pump or install the humidifier lower if possible.
Please note
option: solenoid
valve 0-10 bar
Summary of Contents for HeaterCompact HC02
Page 69: ...Page 69 10 EC Declaration of Conformity...
Page 76: ...Page 76 13 Exploded View...