Figure 11: Bootloader section of LumaConf for upgrading the firmware or factory reset of LUMA X
Discover
Query and display all connected LUMA X.
Reset all
Reset all connected LUMA X
Get info
Retrieve the processor ID of the selected LUMA X
Firmware
(only in serial) selects the firmware cfi file for upgrade
Write
Flash
(only in serial): Programs the firmware to the LUMA X. It is completed once the
transfer progress bar reaches 100%. In case of transfer error, the bar will regress
to 0%
Clear
settings
(only in serial): Will factory-reset the parameters on the LUMA X, such as its IP
address and the
config/active
mode into
config
.
Start
application
(only in serial): Will start the LUMA X. Note: power cycling the LUMA X and
closing the Firmware upgrade window will not put LUMA X into bootloader
mode and it will start normally as well.
4.3
Communication test
When two LUMA X are connected via Ethernet and are in
config
mode, a communication test
can be carried out using a simple communication test tool built into
LumaConf
.