    1       19101A010     Capscrew                                              8
    2      00073-001-1    Wire Connector                                     3
    3      14981-001-1    Pipe Plug                                             1
    4      13425-016-1    Nameplate                                           1
    5      04580-001-1    Drive Screw                                          3
    6      01664-008-1    Pipe Plug                                             3
    7      00589-004-1    Bolt Eye                                               2
    8      01124-002-1    Jam Nut                                               2
    9      00975-005-1    Retaining Ring                                     1
  11      00834-002-1    O-Ring                                       SC       2
  12      00568-001-1    Screw Cap                                             2
  13      02603-000-3    Stator Ring                                           1
  14       06106A051     Capscrew (15 & 20 HP 4 Pole)             8

              00178-005-1    Capscrew (All Others)                           8

  15      00975-008-1    Retaining Ring                                     1
  16      02595-003-2    Housing Seal (Present)                         1
  18      00150-040-1    O-Ring                                       SC       1
  19      02596-000-2    Seal Plate (Prior to 3/1/74)                 1

              02596-003-2    Seal Plate (Present)                              1

  20      01957-000-1    Shaft Seal Ceramic                     SC   1 or 2

              01957-002-1    Shaft Seal Opt. Carbide               C       1

                                      (Bottom Seal Only)

  26      02855-001-1    Key                                                      1
  27       01945-000-1     Shaft Holding Washer (Up to 25 HP)             1

              00156-011-1    Shaft Holding Washer (25–35 HP)            1

  28        570-018-1           Capscrew (Up to 25 HP)                       1

              04834-000-1    Imp. Nut (25–35 HP)                           1

  29      02921-001-1    Flat Hd. Screw                                      4
  30      06958-000-2    Impeller 12" Dia.                                 1

              06958-001-2    Impeller 11.5" Dia.                               1
              06958-019-2    Impeller 11.25" Dia.                             1
              06958-014-2    Impeller 10.31" Dia.                             1
              06958-004-2    Impeller 10" Dia.                                 1
              06958-013-2    Impeller 9.25" Dia.                               1
              06958-012-2    Impeller 8.63"  Dia.                             1
              06958-011-2    Impeller 7.88" Dia.                               1

  31      00150-026-1    O-Ring                                       SC       1

  33      10783-000-2    Volute                                                  1
  34      00150-003-1    O-Ring                                       SC       1
  35      08472-003-5    Sensor Assy. (Present)                           1
  36      02602-000-3    Sleeve                                       SC       1
  37      00975-006-1    Snap Ring                                             1
  38       19105A033     Capscrew                                              8
  40      00150-025-1    O-Ring                                       SC       1
  41      00065-026-1    Lower Bearing (Present)                       1
  42      00568-006-1    Bolt                                                     8
  45      02597-002-2    Motor Housing for use with                   1

                                      20 HP & below

              04832-001-2    Motor Housing for use with                   1

                                      25 HP & above, 15 HP 1150 RPM

  46              RTF           Stator 2 to 5 HP, 230/460/3/60, 

                                      870 RPM VFD Stator                             1

                    RTF           Stator 2 to 5 HP, 200/3/60, 

                                      870 RPM VFD Stator                             1

                    RTF           Stator 2 to 5 HP, 575/3/60, 870 

                                      RPM VFD Stator                                    1

                    RTF           Stator 3 to 15 HP, 230/460/3/60, 

                                      1150 RPM VFD Stator                           1

                    RTF           Stator 3 to 15 HP, 200/3/60, 

                                      1150 RPM VFD Stator                           1

                    RTF           Stator 3 to 15 HP, 575/3/60, 

                                      1150 RPM VFD Stator                           1

                    RTF           Stator 10 to 20 HP, 230/460/3/60,

                                      1750 RPM VFD Stator                          1

                    RTF           Stator 10 to 20 HP, 200/3/60, 

                                      1750 RPM VFD Stator                           1

                    RTF           Stator 10 to 20 HP, 575/3/60, 

                                      1750 RPM VFD Stator                           1

                    RTF           Stator 25 to 35 HP, 230/460/3/60,

                                      1750 RPM VFD Stator                           1

                    RTF           Stator 25 to 35 HP, 575/3/60, 

                                      1750 RPM VFD Stator                           1

  47              RTF           Rotor & Shaft, 2 to 5 HP, 870 RPM       1

                        RTF             Rotor & Shaft, 3 to 15 HP, 1150 RPM       1

Ref.         Part         Part

  No.          No.          Description                               Qty.

                        RTF              Rotor & Shaft, 10 to 20 HP, 1750 RPM        1
                        RTF              Rotor & Shaft, 25 to 35 HP, 1750 RPM        1

    48          06000-003-5       Wire & Terminal Assy. (Prior to 5/1/78)           1

              06000-021-1    Wire & Terminal Assy. (Present)            1

  49      00065-006-1    Upper Bearing                                     1
  50      01006-001-1    Wire Conn. 230/460V                          9

              01006-001-1    Wire Conn. 200/575V                          3

  51      00282-001-1    Wire Connector                                     3
  52      00150-007-1    O-Ring                                       SC       1
  53      00853-000-1    Wire Conn. 200V 10/4 Cord                 3

              02494-000-1    Wire Conn. 200V 8/4 Cord                   3
              02494-000-1    Wire Conn. 230V                                  4
              00853-000-1    Wire Conn. 460V 10/4 Cord                 6
              02494-000-1    Wire Conn. 460V 8/4 Cord                   3
              00853-000-1    Wire Conn. 460V 8/4 Cord                   3
              00853-000-1    Wire Conn. 575V 10/4 Cord                 3
              02494-000-1    Wire Conn. 575V 8/4 Cord                   3

  54      06237-000-5    Conn. Box Assy. 230/460V                   1

              06237-001-5    Conn. Box Assy. 200/575V                   1

  55      05465-040-5    Cord Cap Assy. 30' Dual 10/4               1

              05465-041-5    Cord Cap Assy. 30' Dual 8/4                1
              05465-042-5    Cord Cap Assy. 30' Dual 6/3                 1
              05465-043-5    Cord Cap Assy. 30' Dual 4/3                 1

  56      00150-012-1    O-Ring                                       SC       1
  57      00064-005-1    Bearing Spring                                     2

                                      (None Required Prior to 2/14/78)

  58      07665-001-1    Spacer for New Style Stator                   1

                                      3 to 15 HP, 1150 RPM

  58      07665-000-1    Spacer for New Style Stator                   1

                                      10 to 20 HP, 1750 RPM

  59      02583-002-1    Pipe Plug 25 HP & Up                           2

              51700-019-7    Seal Kit                                         
              51700-319-7    Carbide Seal Kit

  60     24709110000   Paraffinic Oil                              O

ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be fur nished
as  long  as  it  is  in ter change able  with  the  old  part.When  ordering  re place ment  parts,  always  furnish  the  fol low ing  information: 
(1) pump serial num ber, (2) pump model and size, (3) part description, (4) part number, (5) im pel ler diameter (if ordering impeller),
(6) quan ti ty required, and (7) shipping instructions.

Ref.         Part         Part

  No.          No.          Description                               Qty.

Ref.         Part         Part

  No.          No.          Description                               Qty.

S4LRC
Parts List

NOTE:  S — Parts in Seal Kit.  C — Parts in Carbide Seal Kit.  RTF — Refer To Factory

            O — Amount of oil required will vary between 11 and 13 qts. depending on stator size. Fill oil to above motor windings.

For use with product built with GE motor.

Summary of Contents for S4LRC

Page 1: ...03 315 Part 5625 315 1 2011 Pentair Pump Group Inc NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system Installation and Service Manual For use with product built with GE motor ...

Page 2: ...connected in series with the motor starter coil so that the starter is tripped if heat sensor opens The motor starter is equipped with 3 leg overload heaters so all normal overloads are protected by the starter IMPORTANT If Hydromatic electrical starting equipment is not supplied the heat sensor circuit must be connected in series with the starter coil or warranty on motor is void Connection diagr...

Page 3: ...low inflow capacity Electrical Control Panel It is recommended that the Hydromatic control panel be used with all pumps as proper starter heaters and connections for heat sensor wires are furnished IMPORTANT If Hydromatic electrical controls are not used and the motor fails because of improper components or if the heat sensors are not properly connected the motor guarantee is void Hydromatic elect...

Page 4: ...etimes installed without a check valve where it is desirable to self drain the discharge line to prevent freezing This can be done only with short discharge lines otherwise water will return to the sump and cause short cycling of the pump NEMA 4 Junction Box Optional If electrical control panel is to be set remote from the pump sump a NEMA 4 junction box should be used to make power and control co...

Page 5: ...a see Addendum S4LRC 701 Heat Sensors and Seal Failure Connections Be sure that heat sensor wires are connected in series with the starter coil Connections are provided on the terminal strip see wiring diagram If seal failure unit is used connect as shown with seal failure system If seal failure unit is not used the two seal failure wires are left open Do not connect power to these lines at any ti...

Page 6: ...ightning occurs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost are available from the factory Lightning arrestors are good insurance against damage to an expensive motor Servicing Instructions WARNINg Before handling these pumps and controls always disconnect the power first Do not smoke or use sparkable electrical device...

Page 7: ... into the stator This holding spot is drilled through the bolt hole when the stator is bolted in place with the end ring 11 Replace stator housing onto seal chamber and bolt in place BE SURE SEAL FAILURE WIRE IS CONNECTED BEFORE HOUSINg IS ASSEMBLED Be sure back off screws have been loosened so that parts can come metal to metal Be sure O ring seal has been replaced If O ring is nicked or cut repl...

Page 8: ...Megger for grounds before operating the pump Below is a list of common problems and the probable causes WARNINg Before handling pumps and controls always disconnect power first Do not smoke or use sparkable electrical devices or flame in a septic gaseous or possible septic sump Pump will not start 1 No power to the motor Check for blown fuse or open circuit breaker 2 Selector switch may be in the ...

Page 9: ...be installed on pump side of all valves Multiply gauge pressure in pounds by 2 31 to get head in feet 5 If pump has been in service for some time and capacity falls off remove pump and check for wear or clogged impeller Motor stops and then restarts after short period but overload heaters in starter do not trip 1 This indicates heat sensors in the motor are tripping due to excessive heat Impeller ...

Page 10: ...o 20 HP 575 3 60 1750 RPM VFD Stator 1 RTF Stator 25 to 35 HP 230 460 3 60 1750 RPM VFD Stator 1 RTF Stator 25 to 35 HP 575 3 60 1750 RPM VFD Stator 1 47 RTF Rotor Shaft 2 to 5 HP 870 RPM 1 RTF Rotor Shaft 3 to 15 HP 1150 RPM 1 Ref Part Part No No Description Qty RTF Rotor Shaft 10 to 20 HP 1750 RPM 1 RTF Rotor Shaft 25 to 35 HP 1750 RPM 1 48 06000 003 5 Wire TerminalAssy Priorto5 1 78 1 06000 021...

Page 11: ...11 S4LRC 55 56 54 3 53 52 50 51 49 48 47 46 45 41 42 40 35 36 38 31 33 30 37 34 28 27 26 20 2 4 5 6 7 60 8 57 9 11 12 13 14 15 16 18 19 1 29 58 ...

Page 12: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 13: ...__________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ _____________...

Page 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Page 15: ......

Page 16: ...g Line Voltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well Yes No Are Floats Set to Engineer s Specs Yes No Are Floats Wired for Proper Seq...

Reviews: