Hydromatic S3SD Manual Download Page 1

NOTE! To the installer: Please make sure you provide 
this manual to the owner of the pumping equip ment or to 
the responsible party who maintains the system.

Submersible Sewage Pump

Dual Seal Pumps

S3SD/S4SD &

SB3SD/SB4SD

Part #  5625-420-1           

Item # E-03-420   04/09

Summary of Contents for S3SD

Page 1: ...ase make sure you provide this manual to the owner of the pumping equip ment or to the responsible party who maintains the system Submersible Sewage Pump Dual Seal Pumps S3SD S4SD SB3SD SB4SD Part 5625 420 1 Item E 03 420 04 09 ...

Page 2: ... panel Sump Level Control Sump level is controlled by Hydromatic 3900 mercury switch level controls The 3900 level controls is a metal case mercury switch sealed in a solid polyurethane float The float is held in position by a weight at tached to the power cord above the float The cord supports the float and is adjusted for height from the sur face Typical duplex systems use three floats the lowes...

Page 3: ...ump Nema 4 Junction Box Optional If electrical control panel is to be set re mote from the pump sump a NEMA 4 junc tion box should be used to make pow er and control con nec tions The Hydromatic NEMA 4 junc tion box is pro vid ed with com pres sion con nec tors for seal ing all wires No sealing com pound is need ed to make con nec tions waterproof NUMBER OF CONDUCTORS REQUIRED BETWEEN CONTROL PANE...

Page 4: ... ces sive solids may collect for the pump to han dle A frequent pump ing cycle is rec om mend ed for best op er a tion If an alarm system is used this con trol is usually set about 6 inch es above the over ride control Some engineers as de scribed pre vi ous ly prefer to have the alarm control set be low the override control Making Electrical Connections All electrical wiring must be in ac cor dan...

Page 5: ...ls always dis con nect the power first Do not smoke or use sparkable elec trical devices or flames in a sep tic gas eous or possible septic sump Field Service on Motor All submersible motors can be ser viced out of warranty in the field by any reliable motor service shop Any pump in warranty must be re turned to the factory for ser vice or repaired in an au tho rized Hydromatic ser vice center Cha...

Page 6: ...l oil cov ers top of wind ings Leave air space in top for ex pan sion Use Permatex on plug threads Replacing Seals and Bearings 1 Drain all oil from motor chamber as described 2 Remove bolts that hold motor hous ing to bearing housing Re move screws hold ing bearing housing to volute housing 3 Lift rotating assembly rotor shaft and impeller from pump case and place hor i zon tal ly on bench With h...

Page 7: ... on power and if pump starts trouble is in float con trol Replace control Pump Troubleshooting Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several min utes then restart 2 Lower float control may be hung up in the closed po si tion Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver prop er capacity ...

Page 8: ...te 1 18 00975 012 1 Snap Ring 1 19 08908 002 1 Key Square 1 20 10108 000 1 Washer Impeller 1 21 19101A003 Screw Cap 1 22 09927 123 2 Impeller 1 5 HP 1 09927 124 2 Impeller 1 HP 2 HP 1 09927 125 2 Impeller 3 HP 1 23 06106A019 Screw Cap 5 24 07990 002 2 Plate Seal 1 8 Ref Part Part No No Description Qty 25 00150 019 1 O Ring 1 26 19103A043 Screw Cap 4 27 08206 000 1 Inst Plate 1 28 07145 000 2 Housi...

Page 9: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 22 24 25 30 29 28 27 38 26 23 31 15 32 33 34 35 36 37 9 S3SD ...

Page 10: ...p Ring 1 19 08908 002 1 Key Square 1 20 10108 000 1 Washer Impeller 1 21 19101A003 Screw Cap 1 22 09927 123 2 Impeller 1 5 HP 1 09927 124 2 Impeller 1 HP 2 HP 1 09927 125 2 Impeller 3 HP 1 23 06106A019 Screw Cap 5 24 07990 002 2 Plate Seal 1 Ref Part Part No No Description Qty 25 00150 019 1 O Ring 1 26 19103A043 Screw Cap 4 27 08206 000 1 Inst Plate 1 28 07145 000 2 Housing Bearing 1 29 00568 007...

Page 11: ...11 SB3SD 2 1 10 3 4 5 6 7 8 9 11 12 13 14 15 16 17 44 42 43 24 23 22 21 20 19 18 38 27 28 29 30 39 41 26 25 31 15 32 33 40 34 35 36 37 ...

Page 12: ...16 00150 029 1 O Ring 1 17 09995 101 2 Volute 1 18 00975 012 1 Snap Ring 1 19 08908 002 1 Key Square 1 20 10108 000 1 Washer Impeller 1 21 19101A003 Screw Cap 1 22 09978 031 2 Impeller 3 HP 1 09978 031 2 Impeller 2 HP 5 HP 1 09978 129 2 Impeller 7 5 HP 1 23 06106A019 Screw Cap 5 Ref Part Part No No Description Qty 24 07990 003 2 Plate Seal 1 25 00150 023 1 O Ring 1 26 19103A043 Screw Cap 4 27 0820...

Page 13: ...13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 38 27 28 29 30 23 31 15 32 33 34 35 36 37 S4SD ...

Page 14: ...7 09995 101 2 Volute 1 18 00975 012 1 Snap Ring 1 19 08908 002 1 Key Square 1 20 10108 000 1 Washer Impeller 1 21 19101A003 Screw Cap 1 22 09978 031 2 Impeller 3 HP 1 09978 031 2 Impeller 2 HP 5 HP 1 09978 129 2 Impeller 7 5 HP 1 23 06106A019 Screw Cap 5 24 07990 003 2 Plate Seal 1 25 00150 023 1 O Ring 1 Ref Part Part No No Description Qty 26 19103A043 Screw Cap 4 27 08206 000 1 Inst Plate 1 28 0...

Page 15: ...15 2 1 10 3 4 5 6 7 8 9 11 12 13 14 15 16 17 44 42 43 24 23 22 21 20 19 18 38 27 28 29 30 39 41 26 25 31 15 32 33 40 34 35 36 37 SB4SD ...

Page 16: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 17: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 18: ...operly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installatio...

Page 19: ......

Page 20: ...___________________________ D Incoming line voltage _________________________ Actual _____________________________ E Voltage to pumps ____________________________ Actual _____________________________ F Type of junction box _____________________________ Manufacturer _______________________ G Are floats installed in wet well _______________________________________________________ H Are floats set to...

Reviews: