2
Thank you for purchasing your
Hydromatic
®
pump. To help
ensure years of trouble-free
op er a tion,
please
read
the
fol low ing manual carefully.
Before Operation:
Read the following in struc tions
care ful ly. Reasonable care and
safe meth ods should be practiced.
Check
local
codes
and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product. Read this manual
completely before using this
product and refer to it often for
con tin ued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MAN U AL. Keep it
in a safe place so that you may
refer to it often.
Unpacking Pump:
Remove pump from carton. When
un pack ing
unit,
check
for
con cealed damage. Claims for
damage must be made at the
receiving end through the delivery
carrier. Dam age cannot be
processed from the factory.
WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
IMPORTANT — Read all the
directions before replacing
any parts.
WARNING: Before handling
these pumps, always disconnect
the pow er first.
Do not smoke or use sparkable
elec tri cal devices or flames in a
septic (gaseous) or possible
septic sump.
Shipping:
When unpacking unit check for
con cealed damage. Claim for
damage must be made at the
receiving
end
through
the
delivering carrier. Dam age cannot
be processed from the fac to ry.
Pumps Not Operating or
in Storage:
Pumps with carbon ceramic seals
must have impellers manually
rotated (6 revolutions) after
setting non-op er a tion al for 3
months or longer and prior to
electrical start-up.
Pumps with tungsten carbide seals
must have impellers manually
rotated (6 revolutions) after
setting non-op er a tion al for 3
weeks or longer and prior to
electrical start-up.
Pump:
The submersible pump is sup plied
for three phase only and for 460
and 575 volts. Pump is sup plied
with 35 feet of power cord and/or
35 feet of auxiliary control cord.
Longer cable lengths can be
furnished but must be specified at
time of order. Power cable is three
General
Information
The
Pump
wire with ground. Be sure ground
wire is con nect ed to a water pipe
or ground stake. The auxiliary
cable for seal fail ure and heat
sensors is four wire color coded.
Seal Failure:
An electrode probe is installed in
the seal chamber so if any water
enters the chamber through the
first seal the electrode will be
energized and a sig nal will be
transmitted to the sens ing unit at
ground surface causing a red light
to turn on. The electrode probe is
installed in all units but the
sensing unit is supplied at extra
cost and must be ordered.
In operation the seal failure unit
in di cates only that there is some
water in the seal chamber. The
pump will con tin ue to operate
without damage but the seal
should be checked im me di ate ly
after failure is indicated.
The sensing unit is recommended
on all installations as good
insurance against motor failure.
Heat Sensors —
Standard Equipment:
All motors have heat sensor units
em bed ded in the motor winding to
detect excessive heat. The heat
sen sors are set to trip at 150°C
(302°F), so will not op er ate unless
dangerous heat occurs. The
sensors automatically reset when
mo tor cools to safe tem per a ture.
The sensors are connected in
series with the motor starter coil
so that the starter is tripped if heat
sensor opens. The motor starter is
equipped with overload heaters so
all normal over loads are protected
by the starter.
Sump Level Control:
Sump level is controlled by
Hydromatic float switch con trols.