    A1           65-006-1          BEARING – BALL (UPPER)                  R          1

    A2           65-023-1          BEARING – BALL (LOWER)                 R          1

    A3           150-019-1         O-RING                                                          1

    A4           150-032-1         O-RING                                             SC          1

    A5           150-038-1         O-RING                                           SCI          2

    A6           150-057-1         O-RING                                           SCI          1

    A7           150-108-1         O-RING (VITON)                               SC          1

    A8           239-035-1         SCREW – HHC 1/2-13 x 5-1/4                       4

    A9           239-038-1         SCREW – HHC 1/2-13 x 7-1/4                     12

  A10           556-007-1         SCREW – CAP (HEX SOC.)                               6

  A11           557-000-1         CONNECTOR – WIRE                                       3

  A12           975-010-1         RING – RETAINING                                         1

  A13           975-014-1         RING – RETAINING                                         1

  A14         1272-001-3        TUBING – NYLON                                           1

  A15         1664-008-1        PLUG – PIPE 3/8 SKT HD BRASS                    3

  A16         2310-004-3        SLEEVE – SHAFT                               SC          1

  A17         2855-001-1        KEY – SQUARE 3/8                                       1

  A18         2921-001-1        SCREW – CAP (FL. HD SOC)                            4

  A19         4580-001-1        SCREW – DRIVE                                             4

  A20         6000-011-1        WIRE w/TERMINAL 14 GA. RED                       1

  A21         6579-002-1        KEY – SQUARE 1/4                                       1

  A22         7398-000-2        HOUSING – SEAL                                           1

  A23         7400-004-2        HOUSING – MOTOR                                       1

  A24         7401-100-2        HOUSING – BEARING                                     1

  A25         8206-000-1        PLATE – INSTR (DRAIN)                                 1

  A26         8206-001-1        PLATE – INSTR (FILL & DRAIN)                       1

  A27         8354-000-3        RING – RETAINING STATOR                             1

  A28         8472-002-5        SEAL FAILURE ASS'Y                                       1

  A29         9176-000-1        SLEEVE – WIRE                                               6

  A30         11065-002-3       SCREEN 3.81 DIA.                                           1

  A31          12672A002         CONNECTOR – BUTT                                       3

  A32         13425-023-1       NAMEPLATE                                                   1

Ref.         Part         Part

  No.          No.          Description                               Qty.

  A33          19101A017         SCREW – CAP HEX SST 3/8                            6

  A34          19103A052         SCREW – CAP HEX SST 1/2                            6

  A35        24709110000       OIL – TRANSFORMER                                   10.5

  A36         13424-004-1       LABEL – HEAT SENSOR                                   1

    C1         3718-000-1        SEAL Carbon Ceramic / Buna-n           S          1

    C2         3718-000-1        SEAL Carbon Ceramic / Buna-n           S          1

    C2         3718-001-1        SEAL Tungsten Carbide / Buna-n         C     Optional

    F1          19109A080         NUT – HEX SST 3/4                                       4

    F2         15175-300-1       BAIL – LIFTING                                              1

    F3          05454A030         WASHER – LOCK 3/4                                     4

    F4          05454A027         WASHER – LOCK 5/8                                     2

    F5         15174-000-1       BRACKET – MOUNTING                                   2

    F6          19105A033         SCREW – CAP HEX SST 5/8                            2

                51700-068-7       Seal Kit                                              S

                51700-368-7       Carbide Seal Kit                                 C

                -24709110000      Paraffinic Oil                                     O           

ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be fur nished
as long as it is in ter change able with the old part.When ordering re place ment parts, always furnish the fol low ing information: (1)
pump serial num ber, (2) pump model and size, (3) part description, (4) part number, (5) im pel ler diameter (if ordering impeller),
(6) quan ti ty required, and (7) shipping instructions.

Ref.         Part         Part

  No.          No.          Description                               Qty.

Ref.         Part         Part

  No.          No.          Description                               Qty.

Motor End
Parts List

Notes: S — Parts in Seal Kit  C — Parts in Carbide Seal Kit  I — Parts in Impeller Kit  R — Parts in Rebuild Kit  *Consult Factory

O — Amount of oil required will vary between 8-10.5 gal. depending on stator size, fill to above motor windings. 

Wet End
Parts List

Item#             Description                     S4T                   S8L                  S12L                 S8LA
                                                                                    Qty.                  Qty.                  Qty.

    D1               SCREW – MACH. FL. HD.              829-009-1 (4)           07597A021 (4)                    ---                    07597A021 (4)

    D2                  WASHER – IMPELLER                   1945-001-3               1945-001-3               1945-001-3               1945-001-3

    D3           SCREW – CAP (HEX SOC.) 3/4           3879-002-1               3879-002-1               3879-002-1               3879-002-1

    D4                            VOLUTE                           13688-000-2               7394-200-2               25457F200               7394-000-2

    D5                       RING – WEAR                       13695-000-3               8345-000-2               24548D000              13535-000-3

    D6                 CLAMP – WEAR RING                         ---                               ---                              ---                     13536-000-3

    D7                     BELL – SUCTION                             ---                               ---                     10587-100-2                     ---

    D8                      STAND – PUMP                              ---                               ---                     10627-000-5                     ---

    D9           SCREW – CAP HEX SST 1/2-13                   ---                               ---                       19106A017                       ---

  D10           SCREW – CAP HEX SST 1/2-13                   ---                               ---                    06106A019 (3)                    ---

  D11           SCREW – CAP SKT HD 1/4-20                   ---                               ---                    19103A052 (8)                    ---

For use with product built with USEM motor.

For use with product built with USEM motor.

Summary of Contents for S12L Series

Page 1: ... 503 320 Frame Part 5625 503 1 2010 Pentair Pump Group Inc Installation and Service Manual NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system For use with product built with USEM motor ...

Page 2: ...ave impellers manually rotated 6 revolutions after setting non operational for 3 weeks or longer and prior to electrical start up Pump The submersible pump is supplied for three phase only and for 460 and 575 volts Pump is supplied with 35 feet of power cord and or 35 feet of auxiliary control cord Longer cable lengths can be furnished but must be specified at time of order Power cable is three Ge...

Page 3: ... panel for making connections An extra set of diagrams is included so that one set can be used in the sump when making connections The size wire to use from panel to sump depends on motor size and distance in feet Be sure each wire is checked so that a wrong connection will not be made An ohmmeter or Megger can be used to check wire continuity Installing Float Switch Controls The controls are supp...

Page 4: ... and 3 Starting System 1 Turn H O A switch to Off position and then turn on main circuit breakers 2 Open all discharge valves and allow water to rise in sump 3 Turn H O A switch to Hand position on one pump and notice operation If pump is noisy and vibrates rotation is wrong To change rotation interchange any two line leads to motor 3ø only Do not interchange main incoming lines If duplex system c...

Page 5: ...ry to completely dismantle pump as stator and housing can be As the motors are oil filled no lubrication or other maintenance is required If a seal failure unit is used no attention is necessary as long as the seal shows satisfactory operation If seal failure is not used the pump should be lifted once every two years and the oil drained from the seal chamber to check for water If the pump is used ...

Page 6: ...sible oil Fill chamber until oil covers top of the windings Leave air space in the top for expansion Use Permatex on plug threads Replacing Seals and Bearings 1 Drain all oil from motor chamber and seal chamber as described 2 Remove motor housing as described 3 Remove bolts that hold seal chamber to pump housing Use back off screws to break loose With hardwood block tape end of impeller to loosen ...

Page 7: ...ective If pump still does not start trouble is in the alternating relay Replace with new relay Pump runs but will not shut off 1 Pump may be air locked Turn pump off and let set for several minutes then restart 2 Lower float control may be hung up in the closed position Check in sump to be sure control is free 3 Selector switch may be in the Hand position Pump does not deliver proper capacity 1 Di...

Page 8: ...8 Motor End Components ...

Page 9: ...9 S4T S8L S8LA S12L Wet End Components ...

Page 10: ...15175 300 1 BAIL LIFTING 1 F3 05454A030 WASHER LOCK 3 4 4 F4 05454A027 WASHER LOCK 5 8 2 F5 15174 000 1 BRACKET MOUNTING 2 F6 19105A033 SCREW CAP HEX SST 5 8 2 51700 068 7 Seal Kit S 51700 368 7 Carbide Seal Kit C 24709110000 Paraffinic Oil O ORDERING REPLACEMENT PARTS Product improvements are made from time to time The latest part design will be furnished as long as it is interchangeable with the...

Page 11: ...75 002 1 3 23394A001 3 8662 011 1 13769 003 5 14161 012 5 14161 603 1 50 230 3 1150 64 005 1 2 2498 009 1 3 8675 000 1 3 11667 000 1 9 8662 004 1 13769 001 5 14160 012 5 14160 003 1 50 460 3 1150 64 005 1 2 2494 000 1 3 2498 007 1 3 8675 000 1 3 8790 000 1 9 8662 004 1 13769 005 5 14160 012 5 14160 003 1 50 575 3 1150 64 005 1 2 2498 007 1 3 8675 000 1 3 23394A001 3 8662 004 1 13769 003 5 14160 01...

Page 12: ... 2 13766 037 5 S4T7500M5 4 75 575 3 2 4 13 13532 109 2 13766 037 5 S4T10000M4 4 100 460 3 1 0 4 14 13532 105 2 13766 036 5 S4T10000M5 4 100 575 3 1 0 4 14 13532 105 2 13766 036 5 S4T12500M4 4 125 460 3 4 0 3 15 13532 101 2 13766 032 5 S4T12500M5 4 125 575 3 4 0 3 15 13532 101 2 13766 032 5 S4T15000M4 4 150 460 3 4 0 3 15 13 13532 126 2 13766 032 5 S4T15000M5 4 150 575 3 4 0 3 15 13 13532 126 2 137...

Page 13: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Page 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Page 15: ......

Page 16: ...oltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well T Yes T No Are Floats Set to Engineer s Specs T Yes T No Are Floats Wired for Proper Seq...

Reviews: