2.O5 Electrical Connections
(continued)
Formula Selector Wiring:
(Metric Models)
With the Metric Multi-Washer 3000 units, the Formula Selector(s) are connected directly to the control board, at the second
level of the X2 terminal block, as shown below.
Brown to “-”, Yellow to “+”, White to A3 and Green to B3.
If multiple
Formula Selectors are being connected, they must be connected in parallel, either at the control board or (recommended)
using a standard terminal box, as shown.
Washer Signal Wiring:
(North America Models)
Be sure the unit is turned off, powered down, before connecting the communication boxes!
The North America Multi-Washer 3000 models use Communication Boxes as the interface between the signals coming from
the washer and the formula programming to deliver certain products at certain times. The simple On/Off signals from the
washer are translated into digital packets of information and transmitted back to the Multi-Washer control board over a digital
network. This allows a single four-wire cable to daisy-chain from one communication box to another, simplifying installation.
The connection at the main panel is on the second bank of Terminal Block X2;
Black to “-”, Red to “+”, White to A1 and
Green to B1
as shown below
.
The four conductor cable runs to the “In” connector of the box closest to the main panel. Any
remaining boxes are connected with a cable running from the “Out” connector to the “In” connector of the next box.
The boxes are identified to the PLC by the DIP switch settings as shown below.
If you are using the Remote Formula
Selection accessory, their DIP switches must be set to match the Communication Box to which they are connected.
Recommended
Comm Box
cable routing
Bottom of Control Cabinet
Inside
Control Cabinet
3-5A Char.C
L(+) N(-) PE
+
+
-
-
DC OK
Ajust
22-28V
Weidmuller
PROeco
Box 1
Box 2
In
Out
In
Out
Other
Boxes
(If any)
Box Identification DIP Switch Settings
= 1
= 2
= 3
Every NA Box
Connection
(top down)
Black
Red
Green
White
PE
N
L
X1
-
-
O14
O13
O12
O11
-
-
O16
O15
X3
A3
A2
+
+
B2
B3
X2
Use
shielded
4-conductor cable!
Recommended
Formula Selector
cable routing
Bottom of Control Cabinet
Inside
Control
Cabinet
Terminal Box
(Not provided)
3-5A Char.C
L(+) N(-) PE
+
+
-
-
DC OK
Ajust
22-28V
Weidmuller
PROeco
PE
N
L
X1
-
-
O14
O13
O12
O11
-
-
O16
O15
X3
A3
A2
+
+
B2
B3
X2
W.E. #1
Formula
Selector
Use
shielded
4-conductor cable!
Note:
Metric and North America models are typically supplied
with cables that use different wire colors (see below).
W.E. #2
Formula
Selector
W.E. #3
Formula
Selector