18
T2™
Fig. 10 Expansion Tank
EXPANSION TANK
145
147
144
143
141
146
Refer to Figure 10
Disassembly
1. Remove all items previously discussed in
their recommended order.
2. Remove the ratchet fastener (147) and
discard.
3. Detach the tube (145) from the tank
fi
tting
(146). The
fi
tting (146) does not need to be
removed – unless, replacing.
4. Remove the screw (144) from the expansion
tank.
5. Remove the tank (143). Do not remove the
hose (141) at this time.
Inspection
1. Inspect all parts for wear or damage. Re-
place if necessary.
Assembly
1. Reassemble all parts in the reverse order
of disassembly.
2. When tightening the fasteners, refer to the
table on page 15 for the required torque
values.
NOTE:
As a general rule, use the low end of
the torque speci
fi
cation on fasteners
when reassembling the unit.