Safety Information
VMU 1 ATEX II 2G IIC T4
en(us)
Page 12 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
DANGER
Wrong ATEX area of utilization
Danger of fatal injury
►
The power unit may be used only in the
indicated equipment group, equipment
category, and zone.
►
Potentially explosive atmospheres in which
vapors or gas/air mixtures may occur only
rarely and briefly.
►
Maximum permissible surface temperature
on components of the VMU must not exceed
135°C / 275°F.
Are the following specifications on the type label of the unit
permissible in connection with use in areas posing an
explosion hazard on site?
- equipment group
- equipment category
- explosion hazard subgroup
- temperature class
Ensure that vapors, gases or mists occurring at the place of
operation belong to explosion groups IIA to IIC.
Make sure that during installation of the unit no potentially
explosive atmosphere, oils, acids, gases, vapors or radiation
are present.
Make sure that the unit is sufficiently ventilated and no
external heat input is present.
Make sure that the ambient temperature is does not exceed
40°C/104°F.