Connecting the unit
VMU 1 ATEX II 2G IIC T4
en(us)
Page 34 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Electrical connection of the unit
DANGER
Electric shock
Danger of fatal injury due to electric shock
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
Check that the voltage and frequency information on the power unit type
label coincides with the predominant voltage supply.
Plug the power unit into a properly fused socket for operation.
Switch the pump on and off briefly to check the direction of rotation (jog
mode). In the event of incorrect direction of rotation, reverse the polarity of
two phases. When viewing from the motor-fan side, the direction of rotation is
to the right, in clockwise direction.
The rotating field of the connection socket must be clockwise. If this is not the
case, then the phases can be rotated in the 16A connection plug with the aid
of the phase changing switch in the plug.
Prior to start up, earth the unit using the ground bond.
Prior to starting up the unit, connect the ground bond
between the unit and the tank to be cleaned.
Check the connection between the tank, unit and the
ground potential for good conductivity.
The stationary wheels of the power unit are electrically