Performing maintenance
OLSW
en(us)
Page 34 / 44
MoWa OLSW 3587900a en-us 2018-08-17.docx
2018-08-17
5. Unscrew the three star grips (10.5) and
remove the element holding plate (10.4)
by lifting them upward.
Remove the coalescing elements and
dispose of them in an environmentally
friendly way.
Insert the new coalescing elements (10.1)
into the housing.
Do not use a hammer, etc.
Position the element holding plate (10.4)
and use it to center the coalescing
elements.
Screw on the three star grips (10.5) and
tighten them.
6. Check the O-ring (10.2) for damage, and
replace it if necessary.
Position the middle container part and
tighten the tensioning clamp with max.
20 Nm.
7. Connect the electrical connector and the
phase boundary sensor together and
secure them by rotating clockwise.
8. Proceed as described in chapter
"Commissioning the OLSW" on page 28.
9. The coalescing housing is now ready for
operation.