Commissioning the OLSW
OLSW
en(us)
Page 28 / 44
MoWa OLSW 3587900a en-us 2018-08-17.docx
2018-08-17
Commissioning the OLSW
Before the OLSW is put into operation, it must first be connected
hydraulically and electrically, as described in the above chapters.
Prior to start up, the coalescing elements must be inserted in the coalescing
tank. See in this connection chapter "Changing the coalescing elements"
Observe the maximum pressure of 6 bar. Provide a pressure limiting device if
necessary.
Proceed as follows for commissioning:
1.
Close the shut-off device on WATER OUTLET.
2.
Open the shut-off device on the WATER INLET.
3.
Fill the coalescing tank.
4.
Open the shut-off device on the WATER OUTLET.
5.
The OLSW is now ready for operation.
Performing maintenance
The OLSW is supplied with an electric differential pressure gauge. The
differential pressure gauge is active as soon as the coalescing elements are
used up.
Every time an element is changed, the housing O-ring is to be checked for
any damage. Replace it if necessary.
WARNING
Hydraulic systems are under pressure
Bodily injury
►
Relieve the pressure before performing any
work.
Summary of Contents for OLSW 20 Series
Page 27: ...Installing the OLSW OLSW en us Page 27 44 MoWa OLSW 3587900a en us 2018 08 17 docx 2018 08 17 ...
Page 42: ......
Page 43: ......