Performing maintenance
OLSW
en(us)
Page 33 / 44
MoWa OLSW 3587900a en-us 2018-08-17.docx
2018-08-17
Changing the coalescing elements
1. Close the ball cocks at INLET WATER
and OUTLET WATER connections.
2. Empty the oil and water present in the
coalescing container through the drain
DRAIN into a suitable reservoir.
3. Release the electrical connection to the
phase boundary sensor by rotating
counter-clockwise (1) and then pull apart
(2).
4. First release the upper tensioning clamp
= 13 mm counterclockwise and take it
off.
Then release the lower tensioning clamp
= 13 mm counterclockwise and take
the middle container part up and off.