OffLine Separator - OLS
Error description/troubleshooting
HYDAC Filter Systems GmbH
en
Page 35 / 56
BEWA OLS 3248771 en 2009-12-16.doc
2009-12-16
Error description/troubleshooting
Error message
Cause
Remedy
The "Heater safety
thermostat" warning
lamp lights up
The safety thermostat in
the heater has
triggered.
The heater is
overheated.
Allow the heater to cool down,
open the cover of the heater.
Reset the safety thermostat
manually.
The "Heater fuse
element" warning lamp
lights up
The fuse element for the
heater in the control
cabinet has tripped.
The electricity
consumption of the
heater is too high.
Reset the fuse element (see
schematics), measure the
electricity consumption of the
heater during operation and
compare it with the
specification listed the type
label on the heater.
If the electricity consumption is
greater than the specified
value, then the heater is
defective. The heater needs to
be replaced.
If this is not the cause, then
Hydac Service should be
consulted.
The "Motor protection
actuation" lamp lights
up
The motor protection
switch for the motor in
the control cabinet has
tripped.
The electricity
consumption of the
motor is too high.
Reset the motor protection
switch (see schematics),
measure the electricity
consumption of the motor
during operation and compare it
with the specification listed the
type label on the motor.
If the electricity consumption is
greater than the specified
value, then the motor is
defective. The motor needs to
be replaced.
If this is not the cause, then
Hydac Service should be
consulted.
"Filter elements
clogged" warning lamp
The prefilter element is
clogged.
Install a new filter element.
"Coalescing elements
clogged" warning lamp
The coalescing
elements are clogged
Install new coalescing
elements.
Summary of Contents for OLS 10
Page 55: ......