Items supplied
NOTICE
Impermissible operating media
The unit will be damaged
►
Use the OLS only in connection with mineral oils or diesel fuels in the
presence of a water content <15% by volume.
Procedural limitations
The use of the coalescing procedure with the OLS has the following limitations:
•
The permissible operating viscosity is 2 … 320 mm/s
2
.
•
Use a heater when dewatering mineral oils with a viscosity >100 mm/s
2
.
•
The dewatering of mineral oil and diesel fuel is possible down to a residual water
content of
≈
100 ppm.
•
Use a prefilter to protect the coalescing elements against dirt particles. The
transport of water drops is not hindered by dirt particles.