HYDAC FILTER SYSTEMS GMBH
Performing maintenance | 8
BeWa OFU 3120755e en-us print
61 / 84
3.
Unscrew the cover (1) of the strainer anticlockwise with
the wrench
= 50 mm.
4.
Remove the strainer (3).
5.
Clean the strainer (3) by washing off with a subsequent
blowing out with compressed air.
6.
Check the seal (2) for damage. Replace it if necessary.
7.
Insert the cleaned strainer (3) in the valve.
8.
Manually screw the cover (1) in with an installed seal (2)
clockwise.
9.
Tighten it with the wrench
= 50 mm.
O
The checking/cleaning of the strainer is complete.