HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 6
BeWa OFU 3120755e en-us print
43 / 84
6.1 Avoiding siphoning
If there is a height difference
ΔH
between the suction side and
pressure side container side / system, the low lying line can
develop a suction effect and trigger the siphoning effect be-
tween the communicating containers / systems. This siphoning
effect also occurs when fluid is pumped in a pre-pressurized
reservoir.
Fig. 9:
Avoiding siphoning
Environmentally tip
Siphoning effect
Reservoir overflowing/leaking = oil spill
u
Remove the ends of the hoses from the reservoir after op-
eration or shut the shut-off device in the suction line.
1
2
3
4
5
6
7
8
9
10