18
EDS 3400
Status: 2018-07-30
HYDAC INTERNATIONAL GMBH
Part No.: 670000 E
Relevant data for IO-Link:
Download the IO Device Description (IODD) from: https://ioddfinder.io-link.com/#/
Features
Block Parameters
Yes
Data Storage
Yes
Profile Characteristic
0x0001 (Device Profile: Smart Sensor),
0x8000 (Function Class: Device Identification),
0x8001 (Function Class: Binary Data Channel),
0x8002 (Function Class: Process Data Variables)
Supported Access Locks
Parameters
Data Storage
Local Parameterisation
Local User Interface
Communication
IO-Link revision
V1.1 / support V1.0
Transmission rate, baud rate
3)
38.4 kBaud (COM2)
Minimum cycle time
5 ms
Process data width
32 bit
SIO mode supported
Yes
M-sequence capability
PREOPERATE = TYPE_0
OPERATE = TYPE_2_2
ISDU supported
3)
Connection with unscreened standard sensor line possible up to a max. line length of 20 m.
19 Order details
EDS 3 4 4 6 - F31 - XXXX - P00
Mechanical connection
4
= G1/4 A ISO 1179-2
Electrical connection
6
= Male M12x1, 4 pole (connector not supplied)
Output
F31 = IO Link interface
Pressure range
0040; 0100; 0250; 0400; 0690
Modification Number
P00 = p
0
-Guard