24
EDS 3000 IO-Link
Edition: 2016-02-04
HYDAC
ELECTRONIC
GMBH
Part No.: 669897 E
19.2 EDS 3000 WITH THIN FILM DMS SENSOR CELL;
RELATIVE PRESSURE STARTING AT 40 BAR (1000 PSI)
EDS 3 4 X 6 - F31 - XXXX - 000
Model (technology)
4
= Thin film DMS, relative
Mechanical connection
4
= G1/4 A ISO 1179-2 (DIN 3852) male thread
(only in conjunction with pressure ranges in bar)
7
= 9/16-18 UNF 2A (SAE6), male thread
(only in conjunction with pressure ranges in psi)
9
= Threaded port DIN 3852-G1/4
(only in conjunction with pressure ranges in bar)
Electrical connection
6 = Male M12x1, 4 pole
(connector not supplied)
Output
F31 = IO Link interface
Pressure ranges in bar
In bar: 0040; 0100; 0250; 0400; 0600
In psi: 1000; 3000; 6000; 9000
Modification number
000 = Standard in bar
400 = Standard in psi